PY80265,05GO953

–19–05JUL06–1/1

Removing Primary Air Cleaner Element

PY1100

–UN–29JUL01

PY1113

–UN–29JUL01

A—Rubber Strap
B—Clip
C—Primary Element

1. Disconnect rubber strap (A) at the front of the canister.

2. Lift clip (B) and pull canister cover.

3. Clean out any dirt in canister taking care not to

damage the secondary filter element.

4. Removal of the secondary element is similar to

removal of the primary element.

IMPORTANT: Remove secondary element (inner

element) ONLY if it is to be replaced.
DO NOT attempt to clean secondary
element. If secondary element is
replaced, install new element
immediately to prevent dust from
entering air intake system. When
replacing the air cleaner canister, make
sure that the dust cup/ejector hose is
facing downward.

PY80265,05GO954

–19–10SEP05–1/1

Cleaning Primary Element

PY1114

–UN–29JUL01

1. Pat sides of element gently to loosen dirt. DO NOT tap

element against a hard surface.

2. clean element with compressed air (below 690 kPa or

100 psi). Hold nozzle next to inner surface, and move
up and down pleats.

IMPORTANT: DO NOT direct air against outside of

element, as it might force dirt through
to inside.

3. Inspect element before reinstalling.

140-8