5.1.7 DISPLAY METHOD WHEN RASTER IS NOT AVAILABLE
In a state where a display screen does not appear due to the failure of this unit, the POWER LED (blue) and LAMP LED (orange) can
light up and display a trouble mode.
The factors in case the power is forcibly shut down at the time of failure are memorized and those are displayed.

EXPLANATION ON ACTION

If NG is detected on an item being diagnosed, turn off the power on this unit. As soon as the power goes off, turn on and off POWER
LED and LAMP LED immediately. After the power is shut down, it becomes impossible to turn on the power until the power cable
is either plugged in or unplugged from the AC outlet.

When [1] and [3] take place at the same time, give priority to [1], and [2] will not take place simultaneously with [1] and [3].

Check item

Contents

Classifi-

cations

LED flash cycle

POWER LED

LAMP LED

Lamp does not light up

Detection of lamp return (LAMP_RTN) signals output
depending on the status of the lamp supply electric
current monitored constantly within the lamp ballast unit.
(H = Off)
[LAMP BALLAST UNIT : CN200 [3pin] ]

3

0.1 sec interval
Simultaneously

0.1 sec interval

Simultaneously

Lamp goes out

Detection of lamp return (LAMP_RTN) signals output
depending on the status of the lamp supply electric
current monitored constantly within the lamp ballast unit.
(H = Off)
[LAMP BALLAST UNIT : CN200 [3pin] ]

3

0.1 sec interval
Simultaneously

0.1 sec interval

Simultaneously

Abnormal DD CPU circuit

Detection of serial communication error between MAIN
DRIVE PWB and RECEIVER PWB.
[IC3701 [5 / 7pin] ] (MAIN DRIVE PWB)

2

-------------------- 0.5 sec interval

Fan lock (stop)

Detection of LOCK signals outputting the operation
(circuit) status of the cooling fan. (H=Abnormal)
[IC8005 : 1 / 2 / 4 / 5-pin] (FAN CONTROL PWB)

1

0.5 sec interval

Alternately

0.5 sec interval

Alternately

Lamp cover open

Detection of the interlock switch status for the lamp cover.
(H = Abnormal)
[S0201] (LAMP COVER SW PWB)

3

0.1 sec interval
Simultaneously

0.1 sec interval

Simultaneously

Abnormal D-ILA DEVICE
temperature

Detection of abnormal inner cabinet temperature. (53°C)
[ IC2001] (TEMPERATURE SENSOR PWB)

1

0.5 sec interval

Alternately

0.5 sec interval

Alternately