Left to r ight, Aj-86 gas - left to right 13, Dr iv e uni t – Jackson AJ-100CS User Manual

Page 21: Left side front view r ight side, Recommended table fabr ication

Advertising
background image

5

1

2

[140mm]

41 [1040mm]

20

3

4

[527mm]

8

3

4

[222mm]

11

3

4

[298mm]

14

3

4

[375mm]

6 [154mm]

30 [763mm]

14 [357mm]

7

1

4

[185mm]

1

1

4

[35mm]

32

3

4

[833mm]

94 [2388mm]

Dr

iv

e

Uni

t

75

1

2

[1918mm]

2

1

2

[61mm]

62

1

2

[1590mm]

34 [864mm]

29 [737mm]

8

1

2

[218mm]

21 [533mm]

25 [635mm]

12 [307mm]

1 [25mm]

25 [635mm]

10 [254mm]

C

B

A

M

4 [102mm]

24 [609mm]

45

3

4

[1161mm]

L

A

102 [2591mm]

23

1

2

[598mm]

6 [152mm]

7 [178mm]

D

E

B

33

1

2

[851mm]

8 [206mm]

Dr

iv

e

Uni

t

1

2

[15mm]

84 [2134mm]

B

A

M

L

Dis

h

Clear

anc

e

W

ith Door

s

O

pen

Rear

of

Mac

h

ine

14 [356mm]

Mi

n

imu

m

10"

H

igh

Tabl

e

B

a

cksplash

Sc

ra

p

Trough

6 [152mm]

T

able to T

able

O

v

er

all

36 [914mm]

31

1

4

[795mm]

6

1

2

[165mm]

26

1

2

[673mm]

6 [152mm]

Left Side

Front View

R

ight Side

C

F

loor

Sink

O

r Dr

ain

W

ith 3" (

76 mm)

Minimum Dr

ain Line

4" (

102 mm)

wide x

16" (

406 mm)

long c

u

tout in Vent Cowl/Splas

h

Shield. Shipped with Cov

e

r Plate.

Mi

n

imu

m

Scrap

T

rough

14 [355mm]

25 [635mm]

21 [533mm]

8 [203mm]

64 [1626mm]

22 [559mm]

Bas

e

U

n

it

Pr

ewas

h

F

Left to R

ight

Legend

A -

Mac

h

ine water

inlet 3/4" NPT

, 180°F

Hi-

temp,140°F

Low-

temp minimum

B -

Elec

tr

ic

al c

onnec

tion

C -

Dr

ain c

onnec

tion 1-

1/2" NPT

D -

Vent c

o

llar

-

O

p

tional

E -

Vent c

o

wl s

tandar

d

F

-

3/4" NPT

180°F

W

a

ter

Inlet for

was

h

tank

fill, final r

ins

e, & tank heating. F

rom gas

boos

ter

heater

. Inter

c

onnec

ting hos

e

pr

ov

ided by

manufac

tur

e

r.

G

-

3/4" NPT

140°F

W

a

ter

inlet for

gas

boos

ter

heater

.

H -

3/4" NPT

180°F

W

a

ter

O

u

tlet

c

onnec

tion to line on dis

h

mac

h

ine.

Connec

tion hos

e pr

ov

ided by

manufac

tur

e

r.

J

-

3/4" NPT

G

a

s

Connec

tion

K -

4" O

D

Vent pipe c

onnec

tion. F

lue to

be ins

talled to meet loc

a

l c

odes

by

ins

talling c

ontr

a

c

tor

.

L -

Pr

ewas

h water

inlet 3/4" NPT

110°F

-140°F

M -

Cold water

ther

mos

tat plumbing

c

onnec

tion 3/4" NPT

-

O

p

tional

Note: All v

e

rt

ic

al dimens

ions

ar

e +/-

1/2" fr

om

floor

due to adjus

table bullet feet.

86 [2184mm]

H

G

J

K

H

G

J

K

66

1

2

[1692mm]

65

1

2

[1666mm]

Pr

ewas

h Plan View Sec

tion

wi

th Col

d

W

a

ter

T

her

mos

tat

16

3

4

[425mm]

16

1

4

[415mm]

L

M

3/4" [19 mm]

T

able T

u

rndown

F

lange 3/4" Max

21" [533 mm]

Rac

k

Rai

l Hei

ght

Abov

e Dis

h

table

1/4" [6mm] -

5/16" [8mm]

Rac

k

Rai

l

Tu

b

T

able

U

s

e Silic

one Sealer

Between T

able and

Lip of Mac

h

ine to

Pr

ev

ent Leak

age

Recommended Table Fabr

ication

N

o

te

: T

ub W

ill Ac

cept

a T

able F

lange

Up to 24 7/8"

[632 mm]

SECTION 1: SPECIFICATION INFORMATION

AJ-86 GAS - LEFT TO RIGHT

13

AJ-64 Conveyor Series Technical Manual 7610-003-30-93

Issued: 05-02-2006 Revised: 09-29-2007

Advertising
This manual is related to the following products: