Push-lock terminal specifications, Other 86, English – Sanyo DSR-3706PA User Manual

Page 87

Advertising
background image

English

Other

86

Push-lock terminal specifications

Input/output terminals

Signal level

Input/output circuit

<ALARM IN>
[0 voltage contact]

<SENSOR ALARM OUT>
[Open collector/1k

Ω, Low Level

active (max. 25 mA)]

<Control terminals>

(Refer to P12)

Remote input
[2 wire voltage control type]
(REMOTE R1, R2)

Date adjustment input
[Zero voltage contact]
(CLOCK IN)

Clock adjustment output
[Open collector/1k

Ω, Low Level

active (max. 25 mA)]
(CLOCK OUT)

Alarm total output
[Open collector/Low Level
active (max. 500 mA)]
(ALARM OUT)

Alarm reset input
[Zero voltage contact]
(ALARM RESET)

Abnormal warning output
[DC5V/5.7k

Ω, Active Low]

(WARNING OUT)

Normal recording area
remaining level warning output
[DC5V/5.7k

Ω, Active Low]

(FULL)

Remaining alarm warning
output
[DC5V/5.7k

Ω, Active Low]

(ALARM FULL)

Series recording connecting
input
[DC5V/5.7k

Ω, Active Low]

(SERIES IN)

Series recording connecting
output
[Open collector/1k

Ω, Low Level

active (max. 25 mA)]
(SERIES OUT)

External timer input
[Zero voltage contact]
(EXIT TIMER IN)

NON REC Output
[DC5V/5.7k

Ω, Active Low]

(NON REC OUT)

0V

Over 100 ms

Open grounded
input

10k

Ω

1k

Ω

100k

Ω

5V

IC
74HC597

Terminal

Open

0V

Motion sensor detection

Alarm recording stop

Terminal

1k

Ω

IC
B U2090

Terminal

1k

Ω

+5V

4.7k

Ω

Microcomputer

0V

Over 100 ms

Open grounded
input

Terminal

10k

Ω

100k

Ω

5V

1k

Ω

IC
74HC597

0V

Approx. 1 second

Open

Terminal

1k

Ω

IC
B U2090

Open

0V

Alarm recording start

Alarm recording finish

Terminal

4.7k

Ω

4.7k

Ω

5V

IC
B U2090

2SD1801

2SA1576

0V

Over 100 ms

Open grounded
input

Terminal

10k

Ω

100k

Ω

5V

1k

Ω

IC
74HC597

Warning condition established
(HDD error, fan error detected)

0V

5V

Terminal

4.7k

Ω

5V

1k

Ω

IC
B U2090

Warning condition established
(normal recording area capacity depleted)

0V

5V

Warning condition established
(alarm recording area capacity depleted)

0V

5V

0V

5V

Over 300 ms

Terminal

10k

Ω

100k

Ω

5V

1k

Ω

IC
74HC597

0V

Open

Over 3 s

Terminal

1k

Ω

IC
B U2090

0V

Over 100 ms

Open grounded
input

Terminal

10k

Ω

100k

Ω

5V

1k

Ω

IC
74HC597

Recording stopped

0V

5V

Terminal

4.7k

Ω

5V

1k

Ω

IC
B U2090

Advertising