Care and maintenance, Humidifying filter – Sharp KC-C100U User Manual

Page 20

Advertising
background image

E-18

CARE AND MAINTENANCE

HUMIDIFYING FILTER

Frequency of maintenance cycle will depend on the hardness or the impurities of the water

that you use; the harder the water the more often descaling will be necessary.

1

6

* Do not scrub the Humid-

ifying Filter, rinse gently

under lukewarm water

only.

5

Remove the Water Tank and

Humidifying Tray.

2

Remove the Humidifying Filter

from the Humidifying Tray.

Avoid spilling water from the Humidifying Tray.

3

Preparing the descaling solu-

tion.

Citric acid, available at some drugstores,

or 100% bottled lemon juice are used

for descaling. Choose either one to use,
and prepare the descaling solution.

Pre-soak the Humidifying Filter

in the solution for 30 minutes

before cleaning.

4

When using lemon juice,

it is recommended to pre-
soak longer than citric
acid.

Rinse the Humidifying Filter

repeatedly with lukewarm water

to remove all the solution resi-

due.

Inadequate rinsing may cause odor and

affect the performance and/or appear-
ance of the unit.

Attach the Humidifying Filter

to the Humidifying Tray, and

replace the Humidifying Tray in

the unit.

•The Humidifying Filter will not fit if

placed in backwards. Be sure there is

no gap between the Humidifying tray

and the unit when the Humidifying Tray

is replaced in the unit. The unit may not
operate properly if the Humidifying Tray
is not properly replaced in the unit.

7

Plug in the unit, turn power ON,

and press the Filter Reset But-

ton on the display more than 3

seconds to reset.

Water Tank

Humidifying
Tray

Humidifying filter

Humidifying
Tray

Pay attention not to spill water when cleaning the filter.

•When not using the

unit for a long pe-
riod of time, dry the
Humidifying Filter
completely before
replacing.

Care Cycle

Once a month or when the Filter Indicator Light is on.

<For using citric acid>

Dissolve 3 teaspoons of citric acid and 2

1/2 cups of lukewarm water in a suitable

container, and stir well.

<For using lemon juice>

100% bottled lemon juice can be used

for descaling. Use only 100% bottled

lemon juice with no pulp (strain juice

if necessary). Combine 1/4 cup lemon

juice and 3 cups of lukewarm water in a

container large enough to hold the Hu-

midifying Filter and stir well.

You may notice reddish-brown or white

deposits forming on the surface of the Hu-
midifying Filter. These impurities (calcium,

etc.) are due to the impurities contained

in tap water; this is not a defect. Replace

the Humidifying Filter when it is covered

completely in white deposits.

KC-C100U_Eng_N.indd 20

07.11.7 1:22:49 PM

Advertising