Figure 11. multiple fan shutdown (interconnect) – System Sensor DH100ACDCLP User Manual

Page 6

Advertising
background image

15

19

14

3

20

1

3

2

Alarm Signal

Aux. Power +

Sup. N. O.

Sup. COM

Aux. Power –

NOTE: Wiring diagram shown is for DH100ACDCLP 4-wire duct

smoke detector system equipped without a control panel.

Alarm
(Red LED)

Power
(Green LED)
Common

APA451

DH100ACDCLP

NOTE: A trouble condition is indicated when the green LED

is not illuminated.

D200-14-00 6 I56-0084-06R

Figure 9. Wiring diagram for DH100ACDCLP
to APA451:

H0158-01

Figure 8. System wiring diagram for 4-wire duct smoke detectors:

Figure 10. Wiring diagram for DH100ACDCLP to
RTS451KEY:

Important Interconnect Notes
• When using the interconnect feature, all

interconnected units must be powered
with the same, independent supply.

• Polarity must be maintained throughout

the interconnect wiring. Connect termi-
nal 12 on unit 1 to terminal 12 on unit 2
and so on. Similarly, connect terminal 1
on unit 1 to terminal 1 on unit 2 and so
on.

• Up to 10 units may be interconnected.

Figure 11. Multiple fan shutdown (interconnect):

1

6

12

16

A

B

C

FAN

CONTROL

SYSTEM

CONTROL

POWER OR

THERMOSTAT

1

6

12

16

A

B

FAN

CONTROL

SYSTEM

CONTROL

POWER OR

THERMOSTAT

DETECTOR 1

C

DETECTOR 2

1

6

12

16

A

B

FAN

CONTROL

SYSTEM

CONTROL

POWER OR

THERMOSTAT

C

DETECTOR 10

OUT TO

10 DETECTORS

MAXIMUM

24V

9

10

AVAILABLE POWER INPUTS

ALARM AUXILIARY CONTACTS

FOR FAN SHUTDOWN, ETC.

16

6

17

7

18

8

N.C.

C.

N.O.

N.O.

C.

N.C.

ALARM AUXILIARY CONTACTS SHOWN IN

STANDBY. CONTACTS TRANSFER DURING

ALARM AS INDICATED BY THE ARROWS.

SUPERVISORY TROUBLE CONTACTS

TROUBLE CONTACTS CLOSED IN ALARM AND STANDBY.

CONTACTS OPEN WHILE DETECTOR PCB OR POWER IS

REMOVED OR WHEN TAMPER FEATURE TIMES OUT. OPEN

CONTACTS SIGNAL TROUBLE CONDITION TO PANEL.

24V

9

10

AVAILABLE POWER INPUTS

ALARM AUXILIARY CONTACTS

FOR FAN SHUTDOWN, ETC.

16

6

17

7

18

8

N.C.

C.

N.O.

N.O.

C.

N.C.

ALARM AUXILIARY CONTACTS SHOWN IN

STANDBY. CONTACTS TRANSFER DURING

ALARM AS INDICATED BY THE ARROWS.

SUPERVISORY TROUBLE CONTACTS

TROUBLE CONTACTS CLOSED IN ALARM AND STANDBY.

CONTACTS OPEN WHILE DETECTOR PCB OR POWER IS

REMOVED OR WHEN TAMPER FEATURE TIMES OUT. OPEN

CONTACTS SIGNAL TROUBLE CONDITION TO PANEL.

14

3

3

14

4

5

ALARM

INITIATION

CONTACTS

CONTACTS SHOWN

OPEN IN STANDBY.

CONTACTS CLOSE

IN ALARM.

4

5

ALARM

INITIATION

CONTACTS

CONTACTS SHOWN

OPEN IN STANDBY.

CONTACTS CLOSE

IN ALARM.

ALARM

INITIATION

LOOP

UL LISTED 4-WIRE

CONTROL PANEL

FIRST DETECTOR IN THE LOOP

DH100ACDCLP

LAST DETECTOR IN THE LOOP

DH100ACDCLP

EOL RESISTOR

SPECIFIED BY

PANEL MANUFACTURER

CONNECT POWER SOURCE

TO APPROPRIATE TERMINALS

OF EACH DETECTOR. SEE

SPECIFICATIONS FOR

ADDITIONAL POWER SUPPLY

INFORMATION.

FOR WIRING OF AUXILIARY

DEVICES, REFER TO

MANUFACTURER'S

INSTALLATION INSTRUCTIONS

OR CONTACT MANUFACTURER.

NOTE: THE SUPERVISORY RELAY NOW

PROVIDES A "FORM C" CONTACT FOR

CUSTOMIZED APPLICATIONS.

FOR STANDARD APPLICATIONS, ONLY

THE "NO" CONTACT IS USED

POWER INPUTS ACCEPT

24 VDC, 24 VAC 50-60 HZ,

CONNECT POWER SOURCE

TO APPROPRIATE TERMINALS

OF EACH DETECTOR.

AUX. CONTACT RATINGS

10A @ 30 VDC RESISTIVE

100mA MINIMUM @ 5 VDC

1/4 HP @ 240 VAC

1/8 HP @ 120 VAC

NOT INTENDED FOR

CONNECTION TO CONTROL

PANELS.

TROUBLE CONTACT RATING

2.0 A @ 30 VDC resistive

2.0 A @ 125 VAC resistive

+

120

VAC

220/240

VAC

A

B

C

220/240

VAC

A

B

C

120

VAC

15

19

14

3

20

2

11

2

6

1

Alarm Signal

Aux. Power +

Sup. N. O.

Sup. COM

Aux. Power –

Reset

Test

(Red LED) Alarm

(Green LED)
Power

DH100ACDCLP

RTS451/RTS451KEY

5

4

3

*

For RTS451KEY
only without a
control panel.

*

CAUTION

Do not loop wire under terminals when wiring detectors. Break wire runs to provide system supervision of connections.

H0155-01

H0156-00

H0157-00