APPLICATION

Adding pool chemicals automatically on a regular basis will
minimize the high and low swings associated with intermit-
tent manual chemical maintenance. By adding chemicals
automatically on a regular cycle, a more consistent level can
be achieved than is possible with weekly or semi-weekly
manual additions. The pump can lift 15 feet from the supply
tank, and push up to 20 feet vertically and 65-70 feet hori-
zontally to the final injection point. Injecting into pressurized
lines up to 30 PSI is possible without special considerations.
The SR-4000 and SR-6000 can also be set on a continuous
setting and cycled by an automatic controller.

Risk of chemical burns and explosion.

Always consult the chemical manufacturer for

proper storage, use, handling and compatability for use
with a peristaltic pump.

Follow all warnings and instructions provided by the

chemical manufacturer.

Never dispense different chemicals through the

same supply tubing.

Always flush the pump and the supply tubing thor-

oughly with water prior to changing to another chemical.

Always inject chemicals into the return line down-

stream from all pool equipment.

Always wear protective clothing and face shield ap-

propriate to the chemical(s) you are handling.

INSTALLATION

Mounting

Mount the SR-4000/SR-6000 Dispenser on a wall near the
chemical supply. The dispenser should be less than 15 feet
from the chemical container and less than 70 feet from the
injection point. Although further distances are possible,
performance may be reduced. Testing is recommended for
greater distances. Use appropriate hardware for the chosen
mounting surface. Mounting location should be protected
from exposure to direct spray and direct sunlight whenever
possible.

Plumbing

Connect the chemical tubing and drum kit following the
instructions included with the plumbing kit. Additional
tubing and hardware may be required depending on dis-
tances and configuration. Secure the injection point as re-
quired for either a pressure line or an open body of water.

OR

Body of Water

SR-4000/
SR-6000

To Pressure
Injection

To Open Body
of Water

Water System
Return Line

3969 0501

Chemical
Supply

Figure 2: Plumbing Setup.

115 VAC Input
from Power Cord
(Standard)

Orange

Red

Black

White

Blue

Yellow

24 VAC
Output to
PCA Board

Blue

Yellow

24 VAC
Output to
PCA Board

208 VAC Input
from Conduit

Orange

Red

Black

White

Blue

Yellow

24 VAC
Output to
PCA Board

230 VAC Input
from Conduit

Orange

Red

Black

White

Figure 3: 24VAC Transformer Connections.