Control description – STA-RITE SR-6000 User Manual

Page 5

Advertising
background image

5

Determine the injections per day required and the duration
time of each injection by using the chart on Page 4.
EXAMPLE 1: 6 doses per day at 25 seconds each will de-
liver 15 ounces per day.
EXAMPLE 2: 8 doses per day at 60 seconds each will de-
liver 48 ounces per day.
Once the required number of injections and the duration
of each dose are determined, set the switches SW1, SW2,
and SW3 for the correct number of injections and the du-
ration of each dose.
Durations of 1-255 seconds with 1-second increments

or 1-255 minutes with 1-minute increments are possible.

Intervals of 15 minutes to 4 weeks are possible (see

Figure 8, Page 6, for a detailed list of possible intervals).

CONTROL DESCRIPTION

Prime Button

Pressing this button activates the pump at full speed. Use
this button to prime and fill the supply and injection lines

Minutes or Seconds Selection (SW2)

The dose duration can be set for minutes or seconds. The
first toggle of the 2 toggle dipswitch SW2 is “DOWN” for
seconds and “UP” for minutes. The second toggle for this
dipswitch is not used. See Figure 5.

Dose Duration (SW1)

The dose duration is the amount of time required for each
dose. The Dose Duration adjustment will set a duration of
from one to 255 units (of either minutes or seconds), but it
doesn’t determine which units to use. To determine
whether duration will be measured in minutes or in sec-
onds, use SW2 “Minutes/Seconds Selection”. Sliding indi-
vidual toggles of SW1 to the “UP” position programs the
dose duration. Multiple toggles can be switched to add to
the total time. See Figures 6 and 7.

If the main circulator pump operates on a timer, the chemi-
cal feeder should only operate when the circulator is run-
ning. In this case, wire the chemical feed pump through
the same timer and adjust the dose duration and interval to
allow for intermittent operation.

2

N

O

1

2

N

O

1

Time Unit

Maximum Setting

Seconds

255

Minutes

255

Figure 5: Minute/Second selection (SW2).

Switch

Toggle

Move to 'UP'

No.

Amount

Position to Add:

1

1

1 Sec. or Min.

2

2

2 Sec. or Min.

3

4

4 Sec. or Min.

4

8

8 Sec. or Min.

5

16

16 Sec. or Min.

6

32

32 Sec. or Min.

7

64

64 Sec. or Min.

8

128

128 Sec. or Min.

Figure 6: Switch functions of “Dose Duration”
dipswitch (SW1).

8

7

6

5

3

2

N

O

1

4

1 2 4 8

16 32 64

128

8

7

6

5

3

2

N

O

1

4

1 2 4 8

16 32 64

128

8

7

6

5

3

2

N

O

1

4

1 2 4 8

16 32 64

128

3974 0501

EXAMPLE 1: SW1 Settings. No switches up (0 Time).

EXAMPLE 2: SW1 Settings for 25 Seconds or Minutes.
Switches 1,4, and 5 up (1+8+16=25).

EXAMPLE 3: SW1 Settings for 120 Seconds or
Minutes. Switches 4,5,6 and 7 up ( 8+16+32+64=120).

Figure 7: Examples of dip switch settings to set dose
durations.