Ethernet cabling, Ethernet cabling -2, Figure 3-1 – SMC Networks 10/100 User Manual
Page 38: Rj-45 connections -2

I
NSTALLING
THE
S
WITCH
3-2
Ethernet Cabling
To ensure proper operation when installing the switch into a network,
make sure that the current cables are suitable for 10BASE-T or
100BASE-TX or 1000BASE-T operation. Check the following criteria
against the current installation of your network:
•
Cable type: Unshielded twisted pair (UTP) or shielded twisted pair
(STP) cables with RJ-45 connectors; Category 3 or better for
10BASE-T, Category 5 or better for 100BASE-TX, and Category 5, 5e,
or 6 for 1000BASE-T.
•
Protection from radio frequency interference emissions
•
Electrical surge suppression
•
Separation of electrical wires (switch related or other) and
electromagnetic fields from data based network wiring
•
Safe connections with no damaged cables, connectors or shields
Figure 3-1 RJ-45 Connections
RJ-45 Connector