C com 16 Front Panel Layout

1 PROGRAM LED’S 1- 8 – When illuminated, indi-

cates the associated Program (1-SMOOTH VOCAL,
2-AGGRESSIVE VOCAL, 3-BASS, 4-SLAP BASS, 5-
ACOUSTIC, 6-FUNK GUITAR, 7-SUSTAIN, 8-PERC 1) is
selected.

2 PROGRAM LED’S 9-16 – When illuminated, indi-

cates the associated Program (9-PERC 2, 10-SOFT,
11-DYNAMIC, 12-ENHANCED, 13-STEREO COMP,
14–STEREO LIMIT,15-STEREO MASTER,16-MANUAL) is
selected.

3 PROGRAM SELECTOR – Rotary encoder control

knob used to select the 16 Programs.

4 GAIN REDUCTION METER - Displays the amount of

Gain Reduction when Compressor circuit is activated.

5 SENSITIVITY - Used to set the minimum signal level

at which the Compressor circuit begins to function.

6 RATIO - Controls the amount of Gain Reduction in

proportion to the amount of signal over the selected
threshold level.


7 RELEASE
- Selects the amount of time the com-

presssor takes to return the signal to the orignal
level.

8 OUTPUT - Used to set the final level after the com-

pression circuit is applied.

9 INPUT/OUTPUT METER - Six segment LED meter

displays the Input or Output signal level based on
the settings of the I/O meter switch.

10 MAINS POWER SWITCH -

When switched on, the

green LED will light, indicating the C com 16 is
powered on and ready for operation.

11 ENHANCER - Activates the C com 16’s Enhancer cir-

cuit which restores the high end loss resulting from
extreme Gain Reduction.

12 ATTACK - Adjusts the amount of time the compres-

sor takes to reach full gain reduction .

13 BYPASS - Used to switch the C com 16’s compression

circuit on and off. The C com 16 is engaged when
the BYPASS LED lights green.