Carrier installation, Carrier removal – StorCase Technology DE100i-SWC User Manual

Page 27

Advertising
background image

StorCase Technology, Inc.

DE100i-SW/SWC User's Guide - Rev. G01

20

Appendix B - Factory-Installed Options

Carrier Installation

Follow the procedures below to install the DE100 carrier into the receiving frame equipped with

the Hot Swap option.

1. Install the carrier into the receiving frame. A "u" will be present on the front panel.

2. Turn the key lock mechanism, located on the front of the receiving frame,

counterclockwise to the ON position. This locks the drive into the receiving frame

and activates the Hot Swap Board. The drive will begin to spin up and the unit

number on the display will begin flashing.

3. After a short length of time the unit display will stop flashing, indicating that the

device is ready to be used.

Carrier Removal

Follow the procedures below to remove the DE100 carrier from the receiving frame equipped

with the Hot Swap option.

1. Verify that the drive is not active. If the system is on a network, make certain other

users are not accessing the target drive, then disable it from the network. Dismount

the drive.

2. Turn the DE100 key lock mechanism (located on the front of the receiving frame),

clockwise to the OFF position. This unlocks the drive from the receiving frame and

activates the Hot Swap Board. The unit ID number on the display will begin flashing.

WARNING:

Be careful not to remove or disturb the carrier unit at this point. Although

the carrier is physically unlocked, the drive requires a minumum of 15

seconds to spin down and is subject to vibration and possible damage

during this period.

3. As the unit ID number flashes, the Hot Swap Board monitors the activity of the SCSI

bus. When activity is no longer present, the Hot Swap Board will remove power from

the drive and then remove the device from the SCSI Bus. The unit number will continue

to flash during this period.

4. After a short length of time the unit display will turn from a flashing unit number to a

steady “u”, indicating that the device is powered down, unlocked and ready to be

removed from the receiving frame.

Advertising