Step 7 step 7 step 7 step 7 – Sprint Nextel Digital Voice DVP 403 User Manual

Page 17

Advertising
background image

Chapter 3:

Chapter 3:

Chapter 3:

Chapter 3: Getting the Voice Mail System Up and Running

Getting the Voice Mail System Up and Running

Getting the Voice Mail System Up and Running

Getting the Voice Mail System Up and Running

Issue 1.6

Issue 1.6

Issue 1.6

Issue 1.6

Getting the Voice Mail System Up and Running

Getting the Voice Mail System Up and Running

Getting the Voice Mail System Up and Running

Getting the Voice Mail System Up and Running –

– 13

13

13

13

STEP 7

STEP 7

STEP 7

STEP 7

Program the

Program the

Program the

Program the

Protegé

Protegé

Protegé

Protegé

®

®

®

®

Phone

Phone

Phone

Phone

System for Voice

System for Voice

System for Voice

System for Voice

Ma

Ma

Ma

Mail

ilil

il

Certain functions in the phone system require specific
programming entries when integrated with Sprint

®

Digital Voice.


Note: If using a phone system other than Protégé, refer to the Release Notes
for Software Versions and the Integration Guide for further options.

Protegé

®

3x8

When installing Sprint Digital Voice on a Protegé 3x8 system, the
following settings must be changed on the phone system through the
System Administrator’s mailbox using a display keyset.

Extension

Extension

Extension

Extension –

– Ring Assignment

Ring Assignment

Ring Assignment

Ring Assignment: Under Extension change Ring Assignment

for all voice mail ports to NO. At default on the 3x8 system all
extensions are assigned to ring for all lines in Day Mode operation. If
the voice mail ports’ ring assignments are YES, then all voice mail ports
will answer incoming calls simultaneously.

Trunkline

Trunkline

Trunkline

Trunkline –

– Voice Mail Group Answer

Voice Mail Group Answer

Voice Mail Group Answer

Voice Mail Group Answer: Program Voice Mail Group

Answer to allow ring in to the Automated Attendant based on the time
of day when the Auto Attendant should answer. If no Automated
Attendant is used, the field should be set to NEVER. The other valid
entries are ALWAYS, DAY or NIGHT.

Call Handling

Call Handling

Call Handling

Call Handling –

– Voice Mail Dialing Ratio

Voice Mail Dialing Ratio

Voice Mail Dialing Ratio

Voice Mail Dialing Ratio: Set both the Tone Time and

Int_Dgt Time to 90.

Control

Control

Control

Control –

– Voice Mail

Voice Mail

Voice Mail

Voice Mail: Program all of the fields in this category as follows:

VM Group Member – enter all the voice mail extensions that are used.
Prefix Codes – ICM/VM: 12

Transfer: 11
Busy FWD: 11
No Ans: 11
Direct FWD: 11

Suffix Code – NULL
Disconnect Digits - 999999

Protegé CTX/MTX/LTX

When installing Sprint Digital Voice on a Protegé CTX, MTX or LTX
system, the following settings must be changed through Remote
Maintenance Programming. Once the changes are complete, connect a
laptop to the Protegé system and send the updated information.

RMP

RMP

RMP

RMP----Programming

Programming

Programming

Programming----Extension

Extension

Extension

Extension----Category 3

Category 3

Category 3

Category 3: Mark all ports that are

connected to Sprint Digital Voice as V.M. The last column on the right
specifies the port type. To change a type, press

e

until V.M. is displayed

in the field. Exit the screen and Save.

RMP-Programming-Call Handling-Voice Mail Function: Using the Down
Arrow, highlight the Disconnect Codes field and enter six of the number nine (9).
Exit the screen and Save.

RMP

RMP

RMP

RMP----Programming

Programming

Programming

Programming----Extension Application

Extension Application

Extension Application

Extension Application---- Uniform Call Distribution

Uniform Call Distribution

Uniform Call Distribution

Uniform Call Distribution----

UCD Settings

UCD Settings

UCD Settings

UCD Settings: Enter the number of the UCD hunt group that will be used
as the voice mail hunt group and press

e

.

From the Parameter

Advertising
This manual is related to the following products: