Sunbeam 696 User Manual

Page 5

Advertising
background image

To Clean Nebulizer and Water Sensor:

Periodically inspect nebulizer and water sensor and keep them free of mineral deposits. Remove the

tank from the unit and empty the reservoir in the bottom of the unit. Clean nebulizer (located in the

bottom of reservoir) with the brush stored in the unit under the tank. Do not scrape nebulizer or

water sensor or clean them with tools that have metal parts. Clean water sensor with the brush.

If instructions are not followed and hard water is used, mineral build-up on the nebulizer will occur.

If nebulizer has accumulated hard water build-up, drain the reservoir, refill it with a white vinegar

and water solution and let it soak for an hour. Then use the brush to loosen build-up on the

nebulizer. Rinse and drain reservoir and wipe clean.

Caution: Minerals in tap water can cause a white dust to

appear on furniture, etc. Distilled water reduces buildup of

mineral scale and white dust. See inside front cover.

To Store Unit:

The original box makes a good storage place for the unit. Make sure tank, reservoir and all parts

are thoroughly dry before storing. If water is left in the unit during storage, water may harden and

leave deposits that can prevent the unit from operating properly. Leave filling door of the tank

loosened to prevent door and gasket from sticking together. This will prolong the life of the gasket.

A NOTE ABOUT HUMIDITY

It is best to keep the humidity level at about 30 to 50 percent relative humidity.

The comfort level of humidity will vary from room to room and with changing room conditions.

In cold weather, windows and even some walls may fog or develop frost from excessive indoor

humidity. If this occurs, reduce the mist intensity setting to avoid damage from condensed water

dripping on sills.

Too much humidity in the room may allow moisture to accumulate on surfaces where bacteria and

fungi can grow. Collected moisture may also harm furniture and walls, especially wallpaper.
To correct for too much humidity, especially in a small room, leave the room door open and-adjust

the mist intensity control setting.

This equipment generafes and uses RF energy and if not installed properly may cause interference

to radio and television reception. This device has been tested and found to comply with part 18 of

the FCC rules. Should interference occur in a particular installation the user is encouraged to try

to correct the interference by one or more of the following measures:

1. Reorient the receiving antenna of your radio or television.

2. Plug receiver into different outlet so that humidifier and receiver are on different branch circuits.

If necessary, the user should consult an experienced radio/television technician for additional

assistance. The user may find the following booklet prepared by the FCC helpful: “How to

identify and resolve radio-television interference problems”. The booklet is available from

the US government printing office, Washington DC 20402, Stock No.: 004000-00345-4. -

4

Advertising