Double insulated tools extension cords, Grounded tools, X-bench accessory control box – Skil 3100 User Manual

Page 4: Save these instructions, Accessory control box, Accessory switch

Advertising
background image

Replace damaged cords immediately.
Use of damaged cords can shock, burn

or electrocute.

Always use proper extension cord. If an
extension cord is necessary, a cord

with adequate size conductors should be used to
prevent excessive voltage drop, loss of power or over-
heating. The table shows the correct size to use, de-
pending on cord length and nameplate amperage
rating of tool. If in doubt, use the next heavier gauge.
Always use U.L. and CSA listed extension cords.

NOTE: The smaller the gauge number, the heavier the cord.

RECOMMENDED SIZES OF EXTENSION CORDS

120 VOLT ALTERNATING CURRENT TOOLS

Double Insulation

is a design concept used in electric

power tools which eliminates the need for the three wire
grounded power cord and grounded power supply system. It
is a recognized and approved system by Underwriter’s Lab-
oratories, CSA and Federal OSHA authorities.

IMPORTANT: Servicing of a tool with double insulation
requires care and knowledge of the system and
should be performed only by a qualified service
technician.

WHEN SERVICING, USE ONLY IDENTICAL REPLACE-
MENT PARTS.

POLARIZED PLUGS. If your tool is equipped with a polar-
ized plug (one blade is wider than the other), this plug will fit
in a polarized outlet only one way. If the plug does not fit fully
in the outlet, reverse the plug. If it still does not fit, contact a
qualified electrician to install the proper outlet. To reduce the
risk of electric shock, do not change the plug in any way.

Double Insulated Tools

Extension Cords

“SAVE THESE INSTRUCTIONS!”

Grounded Tools

Grounded tools must be plugged into an outlet properly
installed and grounded in accordance with all codes and
ordinances. Never remove the grounding prong or
modify the plug in any way. Do not use any adaptor
plugs. Check with a qualified electrician if you are in
doubt as to whether the outlet is properly grounded.

If the tools should electrically malfunction or break down,
grounding provides a low resistance path to carry electricity
away from the user. Improper grounding can shock, burn or
electrocute. Grounded tools are equipped with three
conductor cord and three prong type plugs. Before plugging
in the tool be certain the outlet voltage supplied is within the

voltage marked on the nameplate. Do not use “AC only”
rated tools with a DC power supply.

4.

WARNING

!

X-Bench Accessory Control Box

Accessory Control Box

Only use the accessory control box for power tools designed
for use with accessory insert plates and suggested power
tools in this manual.

It is intended to be the mains switch for benchtop
applications if your Skil power tool is used in the insert plate.

It is also intended as a convenience outlet for use with your
Skil Circular Saw and Miter Saw.

Accessory Switch

The accessory control box has an accessory On/Off switch
with lock off key. Be aware of your position while using the X-
Bench for fast emergency shut off power. Remove lock off
key to disable switch when not in use.

WARNING

!

Tool’s

Ampere

Rating

Cord Size in A.W.G.

Wire Sizes in mm

2

3-6
6-8

8-10

10-12
12-16

25

50

100 150

15

30

60

120

18

16

16

14

.75

.75

1.5

2.5

18

16

14

12

.75

1.0

2.5

4.0

18

16

14

12

.75

1.0

2.5

4.0

16

16

14

12

1.0

2.5

4.0

14

12

Cord Length in Feet

Cord Length in Meters

Advertising