Basic operations, Basic operations 7, Press pause p or ·. recording starts – Sony TC-WE635 User Manual

Page 7: Start playing the program source, For type i or type ii tape for type iv tape, Break out the record-protect tab(s) (see page 18), Rec level dolby nr

Advertising
background image

Basic Operations

Basic Operations

7

For type I or
type II tape

For type IV tape

–4

L

R

a

+8

dB

+4

0

–10

–20

–30

5

Press PAUSE P or ·.

Recording starts.

6

Start playing the program source.

To

Press

Stop recording

p

Start recording from the reverse side

ª twice in Step 5

Pause

PAUSE P. Press the button again to
resume recording.

Take out the cassette

§ after stopping recording

Use the following selectors and control to perform additional
operations

REC LEVEL

DOLBY NR

ª

·

)

§

r

P

R

r

0

p

ª

·

)

(AMS)

ET

RMS

AUTO CAL ( START

P

)

DUBBING A

n

B

CHECK

DISPLAY

DECK A

DECK B

A

+B REC

HIGH/NORMAL

RMS

+

MORY

RESET

MEMORY

TING

REC

PAUSE

REC MUTING

REC

OFF

DOLBY NR

COUNTER

A

B

ON ON FILTER

BACK

FRONT

PHONES

AUTO REC LEVEL

B

C

S

(AMS)

(AMS)

FADER

ARL

SYNCHRO

START (DECK B

P

)

5

0

10

1

9

2

8

3

7

4

6

To record with the Dolby NR

Set DOLBY NR to ON, and select B, C, or S (TC-WE835S only) before you start
recording.

To record FM broadcasts with the Dolby NR

If the FM reception is unsatisfactory, set DOLBY NR to ON FILTER (multiplex
filter) (see page 22).

To adjust the recording level manually

After pressing REC r in Step 4 on page 6, turn
REC LEVEL so that the peak level meters reach
the recommended level for the corresponding
tape type. After completing the adjustments, stop
playing the program source, then continue the
procedure from Step 5.

z

To protect recordings
against accidental erasure

Break out the record-protect
tab(s) (see page 18).

z

The Dolby HX Pro*
automatically works during
recording

Distortion and noise in the
high-frequency response are
reduced to produce high-
quality sound that can be
enjoyed even during
playback on other tape decks.

Note

Even after adjusting the recording
level, distortion may occur
depending on the source that
you’re recording from. If this
happens, turn REC LEVEL
counterclockwise to lower the
level.

* HX Pro headroom extension

originated by Bang & Olufsen
and manufactured under
license from Dolby Laboratories
Licensing Corporation.

“DOLBY”, the double-D
symbol a and “HX Pro” are
trademarks of Dolby
Laboratories Licensing
Corporation.

Advertising