STORAGE

• Clean the unit thoroughly before storage. Do not use
water pressure.

• Always store the unit in a clean and dry facility.

• If the unit will be stored for a prolonged period (over 30
days), add a fuel additive to the fuel tank to prevent the fuel
from gumming. Run engine for a short period to circulate
the additive.

• Replace crankcase oil with new oil.

• Remove spark plugs and pour approximately 1 ounce (30
ml) of engine oil into each cylinder. Replace spark plugs
and crank the engine slowly to distribute the oil.

• Check hydraulic reservoir for water. If water is found,
change the oil and circulate it through the tool hose and
tool. (See "HYDRAULIC SYSTEM MAINTENANCE" earlier
in this section).

• Disconnect tool hoses.

ENGINE MAINTENANCE

Follow the maintenance schedule and general maintenance
instructions in the engine maintenance and operation
manual furnished with the power unit.

HYDRAULIC SYSTEM MAINTENANCE

• Check hydraulic fl uid level daily. Add fl uid per specifi ca-
tions in this manual. (See "HYDRAULIC FLUID" under the
section titled "OPERATING INSTRUCTIONS".

• Remove condensed moisture from the hydraulic
fl uid by pumping the hydraulic fl uid into a 5 gal/20 l con-
tainer through the pressure hose. Make sure the engine is
at idle when performing this procedure. When the hydraulic
reservoir is empty turn the engine off immediately.

• Allow the fl uid to sit long enough for the water to settle to
the bottom of the container. Slowly pour the fl uid back into
the hydraulic tank, avoiding the water at the bottom of the
container.

• Each day, check hydraulic lines and fi ttings for leaks,
kinks, etc. Do not use your hand to perform this check.

• Change the hydraulic fi lter element every 200 hours of
operation. Change more often if cold, moist or dusty condi-
tions exist.

• Check oil cooler for debris. Remove debris with air pres-
sure.