Maintenance, Warning – Sears Craftsman 247.7764 User Manual

Page 17

Advertising
background image

17

MAINTENANCE

Figure 5-2

hyDRAuLIC FLuID AND INLET FILTER

• Check the hydraulic fluid level in the log splitter reservoir tank

before each use. Maintain the fluid level within the range specified
on the dipstick at all times.

• Change the hydraulic fluid in the reservoir every 100 hours of

operation. Follow the steps below:

1. Disconnect the suction hose from the bottom of the reservoir tank.
2. Carefully unthread the inlet filter and clean it with penetrating oil.

See Figure 5-2.

3. Allow the fluid to drain into a suitable container.
4. Reinsert the filter and refill the reservoir with three (3) gallons of oil.

Approved fluids include Dexron® III / Mercon® automatic transmis-
sion fluid or a 10 Weight AW hydraulic oil.

• Maintain the fluid level within the range specified on the dipstick at

all times.

NOTE: Always dispose of used hydraulic fluid and engine oil at
approved recycling centers only.
• Contaminants in fluid may damage the hydraulic components.

Flushing the reservoir tank and hoses with kerosene whenever
service is performed on the tank, hydraulic pump or valve is
recommended. Any repair to the hydraulic components should be
performed by a Sears Service Center.

WARNING

U

se

extreme

caUtion

when

working

with

kerosene

. i

t

is

an

extremely

flammable

flUid

.

hydraulic Filter

• Change the hydraulic filter every 50 hours of operation. Use only a

10 micron hydraulic filter. Order part number 723-0405.

bEAm AND SpLITTING WEDGE

• Before each use, lubricate both sides of the beam (where it comes

into contact with the splitting wedge) with engine oil. The wedge
plate on the log splitter is designed so the gibs on the side of the
wedge plate can be removed and rotated and/or turned over for
even wear.

• Make certain to readjust the adjustment bolts so the wedge moves

freely, but no excess space exists between the wedge plate and the
beam.

ENGINE

Check Engine oil

1. Stop the engine and wait several minutes before checking the oil

level.

2. Remove the oil fill dipstick.
3. Check the oil level on the dipstick. With the engine on level ground,

the oil must be to the FULL mark on the dipstick.

4. Replace the dipstick and tighten.

Changing Engine oil

Only use high quality detergent oil rated with API service classification
SF, SG, or SH. Select the oil’s SAE viscosity grade according to the
expected operating temperature. Follow the chart below:

Colder

5W30

SAE 30

Oil Viscosity Chart

Warmer

Advertising