Transmitting with External Equipment — PTZ control I/F Menu

88

OK/Cancel

Click OK to finalize any changes made to the settings
and send them to the camera.
If you click Cancel, changes made to the settings will be
discarded and the screen will be reloaded with the
current camera settings.

Transmitting with
External Equipment

— PTZ control I/F Menu

When you click

in the Administrator

menu, the PTZ control I/F menu is displayed.
Using this menu, you can input data into the camera
from the computer via a network and output them to the
external serial interface to control a peripheral device.
You can also input data from a peripheral device via an
external serial interface and output them to the computer
via a network.

Standard

Select RS-232C, RS-485 or RS-422.

Termination

This becomes active when you select RS-485 or RS-422.
Select On or Off.

Camera ID

Enter the ID specified by the external device when you
select RS-485 or RS-422.

Mode

Select the mode of data transmission/reception via a
network: TCP port or VISCA protocol.
TCP: Select when you use the TCP port to input and

output data through the external serial interface.
Using this method, you can easily check data
communications through the serial port by DOS
command “telnet [host name] [port number].”
When TCP is selected, the TCP port No. box
becomes active. Type the port number corresponding
to the TCP port. Specify a port number (1024 to
65535) other than Well Known port numbers.

VISCA: Select when you control the camera with

VISCA protocol.

Pelco-D: Select when you control the camera with

Pelco-D protocol.

Notes

• When you execute serial control with VISCA

protocol, match the transmission setting with the
connected controller.