Sanyo INVERTER SPLIT SYSTEM 8.53E+13 User Manual

Page 21

Advertising
background image

21

How to Test Run the Air Conditioner

After turning on power to the air conditioner, use the remote

controller and follow the steps below to conduct the test run.

(1) Set the remote controller in Test Run mode.

(Fig. 59a)

a) Press and hold the ION button.

b) Then press and hold the 1HR TIMER button.

c) At the same time, press the ACL (reset) button once.

Use a pointed object such as the tip of a pen to press

the ACL button.

• After a few seconds, “

” appears and “oP-1” blinks in

the remote controller display area.

(Fig. 59b)

d) Release the 1HR TIMER button.

e) Release the ION button.

(2) Start Cooling mode test run by pressing the ON/OFF

operation button of the remote controller. (Fig. 59a)

• This starts the fan producing uncooled forced air with

the 4 indicator lamps (OPERATION lamp, TIMER

lamp, QUIET lamp, and ION lamp) on the main unit

blinking. (Fig. 59c)

• After 3 minutes, the system shifts into cooling opera-

tion, and cool air will start to be felt. Cool mode test

run is unaffected by the room temperature.

(3) Press the ON/OFF operation button of the remote con-

troller again to stop the test run. (Fig. 59a)

(4) Finally press the ACL (reset) button of the remote con-

troller to release it from Test Run mode to return to nor-

mal mode. (Fig. 59a)

• “

” and “oP-1” will disappear from the remote con-

troller display area.

After the test run is completed, be sure to press the ACL

(reset) button to return to normal mode. The air conditioner

will not operate correctly if this is not done.

IMPORTANT

Fig. 59a

Fig. 59b

Fig. 59c

1HR.
TIMER

ON/OFF
operatio

n

ACL
(Re

s

et)

ION

b

u

tto

n

b

u

tto

n

b

u

tto

n

b

u

tto

n

OPERATION lamp

TIMER lamp

QUIET lamp
ION lamp

05-423 KHS0971-1271 12/13/05 1:23 PM Page 21