Installation and connections, Basic connections, Dsr-3716 – Sanyo DSR-3709 User Manual

Page 12: Connecting rs-485 terminals

Advertising
background image

English

11

3

INSTALLATION AND CONNECTIONS

This section describes how to connect the digital video recorder to video cameras and other devices. Be sure to read the

instruction manuals for each connected device.

z

Improper connections can result in malfunction or the
emission of smoke.

z

A separate power supply is required for operation of
each camera.

The following diagram shows the connections for cameras, monitors, a microphone, and a PC.

The RS-485 terminals are used to connect a system
controller (sold separately) to the digital video recorder.
After connecting the system controller, you will need to
carry out the settings that are given in the <RS-485 SET>
menu. (JP.96)

Pin locations

z

Do not connect to phone line.

A: Non-inverting driver output/receiver input
B: lnverting driver output/receiver input

Basic connections

USB

LAN

TERMINATE

RS-485

OFF ON

A RS-485 B

ALARM IN

AC IN

SENSOR

ALARM OUT

DO NOT CONNECT TO PHONE LINE

C

CLOC

K IN

CLOC

K OU

T

ALA

RM OUT

ALARM

RESET

ALARM

FULL

NON REC

OUT

WARNING O

UT FULL

SERIES OU

T

EXIT

TIMER

IN

SERIES IN

REMOTE

CONTROL

C 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

C 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

C

R1 R2

1

IN

OUT

ALL

RESET

AUDIO

MONITOR OUT

MON2

MIC IN

IN

OUT

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

MAIN

02

01

04

03

Video input

terminal

PC

Monitor

(sold separately)

Video input

terminal

Monitor 2

(sold separately)

120 V-240 V AC

(50/60 Hz)

* If the monitor 2 (MON2) is not synchronized

with the connected cameras, vertical

picture instability may occur upon the

switching of camera video.

Camera

(sold separately)

(1-16)

Microphone
(sold separately)

System controller (sold separately)

VSP-8000/9000

The RS-485 connector is
connected to A or B according
to the type of cable.

DSR-3716

The DSR-3709 can be connected to nine cameras.

*1 Wrap the cable once around the

large core clamp to attach it.

*2 Wrap the cable once around the

small core clamp to attach it.

Connecting RS-485 terminals

1

6

Pin number

Connector A signal

Connector B signal

1

Not used

Not used

2

Not used

Not used

3

A

B

4

B

A

5

Not used

Not used

6

Not used

Not used

e05_l8hbg_us_7.fm Page 11 Thursday, November 25, 2004 3:01 PM