7 troubleshooting, Problem remedy – Shure Conference Phone User Manual

Page 17

Advertising
background image

English

7

16

Green Power LED is off

• Is the power cable plugged in?
• Is the power switch set to ON (I)?
• Check the main fuse in the power socket.

Red Protect LED illuminates

• Check that the maximum permissible number of

consoles has not been exceeded (60).

• Disconnect all consoles and cables. If the LED still

illuminates, send the power supply unit to an
authorized workshop for repair.

• Activate the test mode.
• Connect the consoles and cables one at a time to

the power supply unit and check their functions.

No sound

• Check the volume setting on the chairman console.
• Activate the test mode.
• Check that all Minicon plugs are fully inserted

(locked) into their sockets.

Feedback (whistling)

7 Troubleshooting

Problem

Remedy

• Move the consoles farther apart.
• Reduce the system volume on the chairman

console.

PTT button does not work

• Check the operating mode on the chairman's

console. The PTT button works only in manual
mode.

Delegate microphone cannot be
activated, lightring on
microphone arm blinks

• The maximum number of simultaneously active

microphones has been reached. Increase the limit
or deactivate one of the other microphones.

Echoes and feedback when
system is connected to a distant
party via AEC/Telco Audio
Interface and external telephone
hybrid or videoconference
codec.

• Adjust audio levels of the external telephone hybrid

or videoconference codec.

• Check external telephone hybrid or video-

conference codec if acoustic echo cancellation
(AEC) is activated.

• Redial for a possibly better telephone connection.
• Ask connected distant party to check their system

for correct settings.

Advertising