Hardware Information

7-24

SIMATIC Box PC 620 Manual

A5E00131465-01

2.5” hard disks

internal

X4

170h-177h, 1F0h-1F7h, can be disabled

IRQ14, IRQ15, edge-triggered

44 pin, 2mm male connector (2.5” HD, pri-

mary),

a maximum of two drives are operable

CD ROM

internal

X3

170h-177h, 1F0h-1F7h, can be disabled

IRQ14, IRQ15, edge-triggered

44 pin, 2mm male connector (CD ROM,

secondary slave with connected LS120,

otherwise secondary master),

a maximum of one drive is operable

LS240

internal

X31

170h-177h, 1F0h-1F7h, can be disabled

IRQ14, IRQ15, edge-triggered

1x41 pin (Hirose DF9-41, LS240, secondary

master with connected drive),

a maximum of one drive is operable

TTY transmitter/
receiver

*

internal

X70/71

Connection for TTY transmitter/receiver

hybrid (physical interface)

PS connection

for 3.5” hard

disk

internal

X25

Power supply for 3.5” hard disk,

4 pin, male connector

PS connection

for CPU fan

internal

X29

Power supply for CPU fan,

3 pin, male connector

PS connection

for device fan

internal

X28

Power supply for device fan,

2 pin, male connector

Backup battery

internal

X24

Power supply for device fan,

2 pin, male connector

*

Optional product feature

Port to the Bus Unit

The Box PC has a bus unit with a PCI slot and a shared ISA /PCI slot. Expansion
cards can be installed to ISA specification (Rev. 3.1) and PCI specification (Rev.
2.0) with a maximum length of 265mm (175 mm for shared ISA/PCI modules). All
the PCI slots can be used as masters. Only 5V PCI modules are operable.

The bus unit is executed as a purely passive module, i.e. there are only socket
contacts for the expansion cards and any necessary backup capacitors. The power
supply to the expansion cards is effected via the connection of the bus unit with the
basic board. The -5V voltage is not provided for in the power supply and is
produced from the -12V on the bus unit via in-phase voltage control.