2.0 QUICK START

2.1 Overview

The Gas Sensor Module has been supplied factory
calibrated and ready for immediate installation and
operation. An installer familiar with installation and
operation of gas detection products can use this
section to begin immediate use of the monitor.

2.2 Wiring

Each module requires four-conductor wiring (two
wires for power and two wires for the signal).

2.2.1. Model 2050-2060 Series

The Model 2050-2060 series are designed to
mount on any indoor vertical surface. Mount
the monitor in the desired location.

-

The installation must meet any hazard-
ous environmental codes for AC/DC elec-
trical instrumentation.

2.2.2 Wiring Connection

Terminal positions on the electronics board are
as follows:

2.2.3 Start-up & Operation

To begin operation of the Gas Sensor Module
provide 9 - 24 VDC from a regulated power
supply such as one of the Sierra Monitor Alarm
Panels, 2102-XX. Each time the sensor mod-
ule is powered up it will perform a warm-up for
2 - 60 minutes.

During warm-up the monitor will, first, cycle
through safe/alarm/safe condition at one hertz.
This will be followed by a short period of continu-
ous alarm before warm-up is completed.

2.2.4 Configuration

The default configuration for each module is to
operate with a buzzer and a normally operating
open (NOO) relay. The user can change this con-
figuration using the jumpers provided. Refer to
table 6.2.

Term inal Function
TB1-1

+ VDC (9 – 24)

TB1-2 GND

(0VDC)

TB2-1

Relay NC (Norm ally C losed) or
Output to M odel 2102 Safe

TB2-2

Relay Com m on

TB2-3

Relay NO (Norm ally O pen) or
Output to M odel 2102 Alarm

Table 2.1