Schumacher Shumacher Power Inverter PI-200 User Manual

Page 8

Advertising
background image

• 8 •

7. LED INDICATOR AND SHUTDOWN PROTECTION

The LED glows GREEN automatically when plugged into a 12V

DC source, but will not glow under the following conditions:

1. When the power input from the vehicle’s battery drops to

approximately 10 volts, low battery shutdown occurs and

inverter shuts off. Solution: Recharge or Replace the battery.

2. When the power input from the vehicle’s battery exceeds

15 volts, high voltage overload protection occurs. Solution:

Reduce the voltage range to between 12 volts and 14 volts.

3. The continuous load demand from the equipment or device

being operated exceeds the continuous load rating of the

inverter being used. Solution: Use a higher capacity inverter

or lower rated device.

4. The case temperature becomes hot (exceeds 145°F).

Solution: Allow the inverter to cool. Do not block the cooling

slots or air flow over and through the inverter. Reduce the

load on the inverter to the continuous rated output.

RESET: To reset after shutdown occurs:

1. Disconnect the inverter from the 12V power source.

2. Check the source of the problem and correct.

3. Reconnect the inverter to the 12V power source.

NOTE: If the red LED is lit and the green LED is not, see the

Troubleshooting section.

8. IF THE INVERTER FUSE BLOWS

Your power inverter is fitted with a fuse, which should not have

to be replaced under normal operating conditions. A blown fuse

is usually caused by reverse polarity or a short circuit within the

device or equipment being operated.

If the fuse does blow:

1. Disconnect the device or equipment immediately.

2. Find the source of the problem and repair it.

3. Install a new fuse (25A). The fuse can be found on the right

side of the inverter.

NOTE: If you are using the 12V accessory

plug to power the inverter, there is also a 15A fuse in the end

of the plug.

Advertising