FAULT MESSAGES (CONT)

DISPLAYED MESSAGE

CONDITION/INDICATES

CHECK/REPAIR

“Gas Valve Failure”

The control system has not detected any current
through the gas valve after it has been energized.

•

Turn off power - check all wiring and connectors
between the CCB’s J6 Socket (page 35) pins 2
& 15 and the Gas Valve’s solenoid coil. Repair/
replace anything worn or damaged as neces-
sary.

•

Perform close visual inspection of the pins
inside the CCB J6 plug and socket - ensure
plugs and sockets are mating properly and pro-
viding good contact. Repair/replace anything
worn or damaged as necessary.

•

Turn off power - disconnect the Gas Valve wir-
ing plug on top of the Gas Valve solenoid coil.
Check Gas Valve solenoid coil resistance with
an ohm meter at the solenoid coil terminals.
Normal resistance is approximately 7 million
ohms. If the Gas Valve solenoid coil is an open
circuit - replace the Gas Valve.

•

Check for 24 VAC at CCB’s J6 Socket pins 2 &
15 during the Ignition Activation operating state
(the Gas Valve status icon will be visible on the
UIM display during this period.

•

Call the technical support phone number shown
on the water heater labeling for further assis-
tance if the problem has not been corrected
after performing the procedures outlined here.

“Communication Failure”

Loss of communication between the CCB and the
UIM.

•

Turn off power - check the communication cable
connections between the J2 Socket on the UIM
circuit board (page 27) and the CCB J16 Port
(page 35).

•

Try a new communication cable (standard cate-
gory V network cable) between the CCB and the
UIM.

•

Call the technical support phone number shown
on the water heater labeling for further assis-
tance if the problem has not been corrected
after performing the procedures outlined here.