Warning, Caution – Stow Plaster and Mortar Mixer (Gasoline Engine/Electric Motor) MS-93 User Manual

Page 23

Advertising
background image

STOW MS-93 MIXER — OPERATION MANUAL — REV. #5 (03/26/10) — PAGE 23

This section is intended to assist the operator

with the initial start-up of the STOW MS-93H

(gasoline engine) or STOW MS-93E (electric

motor) mixer. It is extremely important that this

section be read carefully before attempting to use

the mixer in the field.
DO NOT use your mixer until this section is thoroughly un-

derstood.

Starting (gasoline only)
The following steps outline the procedure for starting the en-

gine. Depending on the type of engine employed in the mixer

the steps may vary slightly. If your mixer has an electric motor

disregard this section.
1. Move the fuel shut-off lever (Figure 11) to the

ON position.

Figure 11. Fuel Shut-OFF Lever

2. To start a cold engine, move the choke lever (Figure 12)

to the

CLOSED position.

Figure 12. Choke Lever

3. Move the throttle lever (Figure 13) away from the slow

position, about 1/3 of the way toward the fast position.

Figure 13. Throttle Lever

STOW MS-93 PLASTER/MORTAR MIXER — START-UP PROCEDURES

Failure to understand the operation of the STOW MS-93

series mixers could result in

severe damage to the mixer

or

personal injury.

See Figures 5 and 6 for the location of any control refer-

enced in this manual.

WARNING

CAUTION

NEVER operate the mixer in a confined

area or enclosed area structure that

does not provide ample

free flow of air.

General Safety

Respiratory Hazard

Advertising