11. MOVING AND STORAGE INSTRUCTIONS

11.1 Store the charger unplugged, in an upright position. The cord will still conduct electricity

until it is unplugged from the outlet.

11.2 If the charger is moved around the shop or transported to another location, take care to

avoid/prevent damage to the cords, clips and charger. Failure to do so could result in

personal injury or property damage.

12. SPECIFICATIONS

Input

– Slow

– Medium

– Fast

– Engine Start

230V~50Hz

.86A

1.15A

2.85A

8.5A

Output

– Slow

– Medium

– Fast

– Engine Start

6/12V 3A

6/12V 5A

6/12V 20A 105 seconds on / 5A 180 seconds on

12V 90A Peak 150A @ 0V

Weight

12.8 lbs. (5.82 kg)

Reverse Polarity Protection

Yes

13. TROUBLESHOOTING AND ERROR CODES

Error Codes

ERROR

CODE

DESCRIPTION

CAUSE

F01

The battery voltage is still under

10V (for a 12V battery) or 5V

(for a 6V battery) after 2 hours of

charging.

Could be caused by trying to charge a 6 volt

battery on the 12 volt setting, or the battery

could be bad; have it checked or replaced.

F02

The charger cannot desulfate

the battery.

The battery could not be desulfated; have it

checked or replaced.

F03

The battery was unable to reach

the “full charged” voltage.

Could be caused by trying to charge a large

battery or bank of batteries on too low of a

current setting, or the battery may have a

shorted cell. Try again with a higher current

setting, or have the battery checked or

replaced.

F04

The connections to the battery

are reversed.

The battery is connected backwards. Unplug

the charger and reverse the connections to

the battery.

F05

The charger was unable to

keep the battery fully charged in

maintain mode.

The battery won’t hold a charge. Could be

caused by a drain on the battery, or the

battery could be bad. Make sure there are

no loads on the battery. If there are, remove

them. If there are none, have the battery

checked or replaced.

F06

The charger detected that the

battery may be getting too hot

(thermal runaway).

The charger automatically shuts the current

off if it detects the battery may be getting too

hot or the battery may have a shorted cell.

Have the battery checked or replaced.

If you get an error code, check the connections and settings and/or replace the battery.