Maintenance 5-3

5.1. Maintenance schedule

Daily:

Check warning signs on equipment for good legibility and completeness
Clean return air filters and casing (depending on dust build-up)

Weekly:

Check main switch for proper function
Check the signal lamps for proper functioning

Every three months:

Clean filter of the regeneration blower (depnding on amount of dust
collected)

Every six months:

Change return air filters (depending on dust build-up)
Clean air filter of the suction box
All electrical and mechanical connections should be checked to see if
they fit securely

Annually:

Dewpoint should be checked (only by Sterling service personnel)

Whenever the
material is changed:

The drying hopper and suction box must be cleaned

&

The service intervals refer to a 3-shift operation.

F

The given maintenance intervals are average values.

Check whether in your individual case the maintenance intervals
must be shortened.