Important Heater details:

• The maximum temperature for which the spa can be set is

104°F (40°C) and the minimum is 65°F (18°C).

• For North American 2-pump spas powered by a 40 amp

service, jets pump #1 must be set to low speed and jets

pump #2 must be turned off to operate the heater.

• For Export (50 Hz) 2-pump spas powered by a 20 amp

service, jet pump #1 must be set to low speed and jets

pump #2 must be turned off to operate the heater.

• Setting the thermostat at maximum will not accelerate the

heating process. This will only result in a higher ultimate

temperature.

• The heater operates until the water reaches the

programmed “set temperature”, then turns off. The heater

will reactivate after the water cools to approximately 1.5°

below the “set temperature”.

8.

Place Cover On Spa

Keeping the insulating cover in place anytime the spa is not in

•

use will reduce the time required for heating, thereby minimizing

operating costs.

The time required for initial heat-up will vary depending on the

•

starting water temperature.

dANGER:

RISK OF PERSONAL INjURY.

Check water temperature carefully before entering hot tub!

Excessive water temperature can cause burns, welts and

body temperature to rise, hyperthermia (over-heating).

!

decontamination Procedure (Steps 9-15)

Steps 9-15 below are only required when sanitizer levels are unstable

after performing steps 1-6 above. Disregard steps 9-15 below if sanitizer

levels remain stable at 3.0-4.0 ppm chlorine or 2.0-4.0 ppm bromine after

performing steps 1-6 above.

9. Add 2.5 ounces (71 g) of sodium dichlor for every 100 gallons (378

Liters) of water. Refer to the table (page 21) for approximate water fill

volume by model.