Feed pump relocation – Spectra Watermakers VENTURA 150 User Manual

Page 13

Advertising
background image

13

If you do not have adequate space to install the feed pump inlet module it is possible to re-
move and relocate the feed pump. Before you install the module, disconnect the hose that
connects the feed pump to the module plumbing. Remove the cooling fan and the heat sink
from the pump. Both are friction fits with no fasteners. Remove the 4 machine screws hold-
ing the pump to the module.

Feed Pump Relocation

Cooling fan

Heat sink

With the pump on a flat surface. Remove the three
screws that hold the pump head on. See Fig1

Re-orient the pump head 120 degrees. See Fig2

Reinstall the screws and tighten firmly. See Fig3

Now the feed pump may be installed where you wish.
Do not install the pump with the head above the mo-
tor in case of leaks.

Fig 1

Fig 2

Fig 3