Troubleshooting Deluxe Systems

Symptom Cause Remedy

Feed pump runs but no pressure

Feed pump air locked

Pressure relief valve open

Open pressure relief valve to bleed
the air then close to start
Close valve

Feed pump starts but shuts down on
high pressure

Prefilter excessively clogged

Closed valve or blockage in flow

Change filter

Check flow path for closed valve or
kink in hose

Low water production
High amperage
High feed pressure

Strainer or prefilter clogged

Service prefilter and strainer

Low water production,
Low pressure

Pressure relief valve partially open
Worn pump head

Close valve
Check flow should be 1.4 GPM
Replace pump head.

Water production normal
High feed pressure high amperage

Cold seawater temperature
Fouled membrane

Normal condition
Clean membrane

Water production normal
Lower pressure
Lower amperage

Warm sea water or brackish water.

Normal condition

Asymmetrical pressure and flow
readings between pump shifts

Check valve leaking
Failed annular ring
Shaft seal leaking

Contact dealer or see the Clark
Pump repair manual.