Menu setup, Main menu, Keyboard setup – Samsung SSC-5000 User Manual

Page 22: Rs-485 communication setup, Address set, 22_ menu setup

Advertising
background image

22_ MENU setup

MENU setup

MAIN MENU

Press the [MENU] button of the keyboard and a log-in window will appear
as follows.

Using the number keys, enter the correct Operator No. and Password.

MAIN MENU will be displayed on the screen when you complete the log-in
process.

Press the item you want to control on the main menu.
Press the <EXIT> icon in the main menu to return to the camera control
mode.

If the CHECK PASSWORD item is set “Off” in the keyboard setup, press the [MENU] button. MAIN
MENU screen will directly appear without the log-in process.

If you press the [MEMU] button while the OPERATOR’s LEVEL is the MANAGER’s or
OPERATOR’s level, you cannot go into the menu.

KEYBOARD SETUP

On MAIN MENU, press <Keyboard Setup> to call the Keyboard Setup screen.

The KEYBOARD SETUP menu are constituted by 7 main items as follows.

RS-485 COMMUNICATION SETUP

On the Keyboard Setup menu, press <RS-485 Communication Setup>

and the RS-485 Communication Setup menu will appear on the screen.

The default address of the keyboard is 0.

The default Baud Rate of the keyboard is 9600BPS.

The factory default setting of Duplex of keyboard is Half Duplex.

ADDRESS SET

The address of the system keyboard can be set.

Press <Address Set> and the keyboard address input window will
appear as shown in the right figure.

Enter the address by using the number keys and press the [ENTER]
button.
Press the <EXIT> icon on lower left if you want to clear the window
without entering the address.

ADDRESS "0": For only one unit
ADDRESS "1~32": For multiple units connected together

When using multiple units that are connected together, you must select a number between 1 and 32 before use.
If the value is set to "0", this may cause communication to fail and malfunction.

When using multiple units connected together and operating two separate keyboards at the same time, the first keyboard to start
communication takes precedence.

1.

2.

3.

4.

M

M

M
M
M

1.

2.

M

M

M

Login

Operator No.

Password

Clear

Enter

RS-485 Communication Setup

Keyboard

Setup

¨Address Set

0

¨Protocol (Port 1)

SAMSUNG

¨Protocol (Port 2)

SAMSUNG

¨Baud Rate

9600

¨Duplex

Half Duplex

Keyboard

Setup

RS-485 Communication Setup

Change Password

Check Password

On

Register New Operation

Camera Data Download

Camera Data Upload

System Information and Setup

Input Keyboard Address (0~32)

Clear

Enter

Keyboard

Setup

MENU

MAIN

Keyboard Setup

Camera Setup

DVR Setup

000

001

Advertising