Applications

5-41

4.

Set the write strength by moving the Write Att: (attenuation) slide bar to a value in a range
between 0 (full write power) and 255 (low write power/off).

5.

A password is required to lock a tag and/or kill a tag.

Remember the password. Once a tag is locked, it cannot be killed without the
password.

6.

Tap Program Tags. It might take more than one attempt to program the tag.

7.

When a tag is successfully programmed, a status message displays in the Status Message
text box.

8.

Tap Read to read a newly programmed tag.

For a successful tag read, the allowable read distance from the front of the
mobile computer scan exit window to the tag is 0.2 ft. - 10 ft. (0.061 m to 3.1 m).

9.

Tap Done to return to the Gemini RFID window.

To successfully write data to a tag, the tag must be no less than 1 ft (.31 m)
from the antenna and no greater than 2 ft (.61 m) from the antenna.