Control codes summary by code, Programmer's guide pcos series 150 control codes, Summary by code – Star Micronics 150 User Manual
Page 91

Programmer's Guide
PcOS Series 150
Control Codes
Summary by Code
12/14/99
Rev G
Page 81
Control Codes Summary by Code
Normal
ASCII
Second
ASCII
field
Hex Code
IPCL equivalent
code
Description
Page
[NUL]
00
Null
[ENQ]
<n>
05H
Set inquire status.
(Refer to command descriptions.)
62
[BS]
08H
&%BS
Set back space.
16
[HT]
09H
&%HT
Set horizontal tabs.
16
[LF]
0AH
&%LF
Set line feed.
15
[VT]
0BH
&%VT
Set vertical tabs.
20
[FF]
0CH
&%FF
Set form feed.
20
[CR]
0DH
&%CR
Set carriage return.
15
[SO]
0EH
&%MW
Se one-line double-wide print.
33
[SI]
0FH
&%F1
Set 17 cpi.
31
[DC2]
12H
&%F3
Set 10 cpi.
31
[DC4]
14H
&%MN
Cancel one-line double-wide print.
33
[CAN]
18H
&%RP
Clear print buffer.
55
[ESC]
[SI]
1BH,0FH
&%F4
Set 24 cpi.
31
[ESC]
[DC1]
1BH,11H
&%VO
Open for validation.
52
[ESC]
[DC3]
1BH,13H
&%VC
Close for validation.
52
[ESC]
[DC4]
1BH,14H
&%VS
Select validation mode with
autoform sense.
52
[ESC]
[EM] B
<n>
1BH,19H,
42H
&%BH <m
1
>
Set bar code height.
n=0 Restore defaults
n=1-9 Number of passes
(0.11” per pass)
50
[ESC]
[EM] C
<n>
1BH,19H,
43H
&%ZC <m
1
><m
2
>
Set validation clamp delay.
53
[ESC]
[EM] J
<n>
1BH,19H,
4AH
&%BJ <m
1
><m
2
>
Set bar code justification.
50
[ESC]
[EM] V
<n>
1BH,19H,
56H
&%ZV<m
1
><m
2
>
Set validation time-out.
53
[ESC]
# <0>
1BH,23H,
30H
&%QT
Begin HSD mode.
22
[ESC]
$
1BH,24H
Copy ROM character set to RAM
character set.
28
[ESC]
% G
1BH,25H,
47H
&%MI
Begin italics.
38
[ESC]
% H
1BH,25H,
48H
&%CI
End italics.
38
[ESC]
*
<m><n>
1 <n>2
1BH,2AH
Print graphics in mode <m>.
46
[ESC]
! <n>
1BH,21H
&%CS<n>
Select the International Character
Set.
24
[ESC]
- <n>
1BH,2DH
&%CU {n=0}
&%MU {n=1}
Set underline.
n=0 end
n=1 begin
36
[ESC]
0
1BH,30H
&%ST
Set 1/8-inch line space.
18
[ESC]
1
1BH,31H
&%SG
Set 7/72-inch line space.
19
[ESC]
2
1BH,32H
Begin variable line spacing.
(This enables [ESC] A <n>).
19
[ESC]
3 <n>
1BH,33H
&%SV <m
1
><m
2
>
<m
3
>
Set variable space n/216-inch.
Where n=1..255 defines the feed
used by line feed.
18