Chapter 6: operator panel controls, Push buttons - momentary switches, Indicators – Star Micronics 150 User Manual
Page 99

Programmer's Guide
PcOS Series 150
Operator Panel Controls
12/14/99
Rev G
Page 89
Chapter 6:
Operator Panel Controls
Push Buttons - Momentary Switches
The FEED key advances the receipt and journal paper.
The RELEASE key opens and closes the validation clamp. It cycles through open and close mode.
The RESUME key restarts the printer after a failure has been cleared.
Indicators
There are three indicators. They are READY, ALARM, and POWER. The printer can be in any of
the following states.
STATE
READY
ALARM
POWER
(Green
(Red
(Green
Indicator)
Indicator)
Indicator)
Ready (The printer is ready to receive data and print.)
On
Off
On
Not ready
Off
Off
On
Off-line
Ready but waiting for a form
Flash
Off
On
Out of paper
Off
On
On
Menu mode
Flash
Off
Flash
Test mode
Flash
Off
On
Printer fault
Off
Flash
On
Printer failure
Off
Off
Off
Watchdog fault (The printer resets.)