1. Do not operate the oven empty. Either food or water should always be in the oven during operation to absorb

microwave energy.

2. Limit use of metal to those specifi c examples given in this booklet. Generally, metal should not be used in the

microwave oven during operation.

3. Do not heat eggs in the shell. Pressure will build up inside the shell and it will explode. Do not reheat cooked eggs

unless they are scrambled or chopped. Puncture the yolk before heating eggs.

4. Do not heat oil or fat for deep fat frying.
5. Pierce the “skin” of potatoes, whole squash, apples or any fruit, vegetable or meat with a skin covering before

heating.

6. Use only popcorn packaged in special microwavable packages. Pop using 100% power. Listen carefully when

popping corn. When popping slows to one or two seconds between pops, remove from oven. Should you ever
smell scorching, remove bag from oven immediately. If any unpopped kernels remain, do not try to re-pop; it may
cause a fi re.

7. Do not use paper towels, plates or other utensils made from recycled paper for microwave heating. Recycled paper

products may contain certain impurities which could cause the paper to ignite during microwave heating.

8. Stir liquids briskly before heating and allow to stand at least for 20 seconds after heating before stirring or drinking

to avoid eruption.

REMINDERS

SPECIFICATIONS

R-CD1200M

R-CD1800M

R-CD2200M

AC Line Voltage

Single phase 120V, 60Hz,

A.C. only

Single phase 230/208V, 60Hz, A.C. only

AC Power Required

1.9kW

120V-16A

2.7kW

230V-12.3A
208V-13.5A

3.2kW

230V-14A
208V-16A

Output Power Frequency

1200W

1800W

2200W

2450 MHz (Class B/Group 2)

★★

Outside Dimensions

17

1/2

”(W) x 20

1/2

”(D) x 13

5/8

”(H)

445 mm (W) x 520 mm (D) x 346 mm (H)

(including feet)

Cavity Dimensions

14”(W) x 13”(D) x 7

1/8

”(H)

355 mm (W) x 326 mm (D) x 177 mm (H)

Weight

Approx. 65 lbs/29.5 kg

Approx. 70 lbs/32.0 kg

Depth (Door Open)

922 mm 36

1/4

IEC Test Procedure

The International Electrotechnical Commission’s standardized method for measuring output wattage.

This test method is widely recognized.

★★ This is the classification of ISM (Industrial, Scientific and Medical) equipment described in the

In ternational Standard CISPR11.

In Compliance with Standards set by

FCC

Federal Communications Commission Authorized.

DHHS

Complies with Department of Health and Human Services (DHHS) rule, CFR, Title 21 Chapter I, Subchapter J.

Health Canada-Complies with Health Canada, Radiation Emitting Device Regulation for microwave oven.

– This symbol on the nameplate means the product is certifi ed by NSF International (NSF-4).

This symbol on the nameplate means the product is listed by Underwriters Laboratories, Inc. for both
the UL and CSA (Canadian Standard Association) standards.

¤