Instructions for the installer – Smeg SNL574GH User Manual

Page 10

Advertising
background image

Instructions for the installer

30

5.2

Regulation for LPG

Loosen screw A and push support B all the way. Use a double head

wrench to remove nozzle C and assemble the suitable one, following
the instructions indicated in the reference charts, with respect to the
type of gas to use. The screwing torque of the nozzle should never
exceed 3 Nm. Reposition support B so that nozzle C is covered
perfectly.
Move the Venturi tube D to regulate the air flow until distance “X” is
reached indicated in the chart in paragraph “5.4 Regulation of primary
air” and then secure the tube by means of screw A. After the
regulations have been carried out, restore the seals with sealing wax or
equivalent material.

Burner

Rated

heating

capacity

LPG – G30/G31 28/37 mbar

Nozzle

diameter

1/100

mm

By-pass

1/100 mm

Reduced

flowrate

(W)

Flowrate

g/h G30

Flowrate

g/h G31

Auxiliary

1.05

48

30 (1)

380

76

75

Semirapid

1.65

62

30 (1)

380

120

118

Rapid

2.55

76

37 (2)

650

185

182

Rapid large

3.1

85

43

750

225

221

Ultra rapid (5)

3.3

87

55 (4)

1200

240

236

Internal

0.8

42

30 (1)

380

58

57

Double
crown

External

3.3

87

55 (4)

1200

240

236

Fish pan

2

67

43 (3)

750

145

143

(1)= 33 for valveless appliances.
(2)= 40 for valveless appliances.
(3)= 45 for valveless appliances.
(4)= 65 for valveless appliances.