Instructions for the installer – Smeg SNL574GH User Manual

Page 11

Advertising
background image

Instructions for the installer

31

5.3

Regulation for natural gas

The hob has been inspected for G25 (2L3B/P) at a pressure of 25

mbar. To allow the unit to work with this type of gas, perform the same
operations described in paragraph “5.2

Regulation for LPG”, but

choose the nozzles and regulate the primary air for natural gas, as
shown in the following table and in paragraph “5.4

Regulation of

primary air”. After the regulations have been carried out, restore the
seals with sealing wax or equivalent material.

Burner

Rated

heating

capacity

Natural gas – G25 25 mbar

Nozzle diameter

1/100 mm

Reduced flowrate

(W)

Auxiliary

1.05

76

380

Semirapid

1.65

98

380

Rapid

2.7

123

650

Rapid large

3.1

130

750

Ultra rapid

3.3

135

1200

Internal

0.8

67

380

Double
crown

External

3.3

135

1200

Fish pan

2.15

110

750

5.4

Regulation of primary air

Referred to distance “X” in mm.

Burner

G25

25 mbar

G30/G31

28/37 mbar

Auxiliary

1.0

1.0

Semirapid

1.0

1.5

Rapid

0.5

1.5

Rapid large

1.5

10.0

Ultra rapid

1.5

2.5

Internal

4.0

1.0

Double
crown
(6)

External

0.5

8.0

Internal

1.0

1.5

Double
crown
(9)

External

1.0

4.0

Fish pan

1.5

2.5

(*) For burner reference numbers, see page 33.

Advertising