Maintenance, Hours meter, Head cleaning – Sony DSR-85 User Manual

Page 70

Advertising
background image

70

Chapter 6

Maintenance and Troubleshooting

Chapter 6

Maintenance and Troubleshooting

Maintenance

2

Press the

≥ button to select “HOURS METER”.

Hours meter

SYSTEM MENU

SETUP MENU

AUTO FUNCTION

HOURS METER

3

Press the

÷ button.

The cumulative counts by the digital hours meter
are indicated on the monitor screen and the time
counter display.

Digital hours meter indications on the monitor
screen

All four counts (T1, T2, T3, and CT) are indicated on
the monitor screen.

The four-digit value to the left of the slash is the
resettable trip count, and the right value is the
cumulative total from manufacture.

Digital hours meter indications on the time
counter display

One of the four indications appears on the time counter
display at a time. Use the

˘ and ≥ buttons to change

the item displayed.
Initially, only the trip value appears. Hold down the
÷ button to display also the cumulative total from
manufacture, which will appear to the right of the trip
value and the slash.

The following illustrates the digital hours meter
indications on the time counter display in all four
display modes. The right-hand indication for each
display mode is the indication you can view while
holding down the

÷ button on the menu control

panel.

T1 (OPERATION) mode:

Oper. 00000

T2 (DRUM ROTATION) mode:

0000/00000

Drum 0000

T3 (TAPE RUNNING) mode:

0000/00000

Tape 0000

CT (THREADING) mode:

0000/00000

Thread 0000

To end the digital hours meter display

Press the MENU button on the menu control panel.

Resetting the trip values

About this operation, consult your Sony dealer.

Head Cleaning

Always use the PDVM-12CL Cleaning Cassette to
clean the video and audio heads. You can run the
cleaning cassette for 10 seconds per cleaning
operation. Follow the instructions for the cleaning
cassette, as inappropriate use of the cleaning cassette
can damage the heads.

To clean the heads

Insert the cleaning cassette. This automatically starts
cleaning. You cannot operate any tape transport
control buttons other than the EJECT button during the
cleaning operation.
After about 10 seconds, the cleaning cassette will be
automatically ejected.

Monitor screen

Time counter display

Resettable trip counts

Unresettable counts

HOURS METER

T1 00000 X10 HOURS

T2 0000/00000 X10 HOURS

T3 0000/00000 X10 HOURS

CT 0000/00000 X10 COUNT

T1:OPERATION

T2:DRUM ROTATION

T3:TAPE RUNNING

CT:THREADING

Advertising
This manual is related to the following products:

85P