Power, reader, and i/o connection, Power connection, Reader connection – Samsung SSA-P401 User Manual

Page 15

Advertising
background image

English

15

INSTALLATION AND EXTERNAL CONNECTION

POWER, READER, AND I/O CONNECTION

Power Connection

- Connect the plus (+) line of DC 12V to the corresponding port (+12V).
- Connect the GND (-) line of DC 12V to the GND (-) port.

Reader Connection

- Connect the plus (+) line of the reader to the corresponding port (DC +12V).

- Connect the minus (-) line of the reader to the GND (-) port.

- Connect the data 0 line of the reader to its port data 0 (D0).

- Connect the data 1 line of the reader to its port data 1 (D1).

Door Number

External Reader

Internal Reader

Exit Button

Two Door Control

1

Reader #1

Reader #2

None

2

Reader #3

Reader #4

None

Three Door Control

1

Reader #1

Reader #2

None

2

Reader #3

None

Internal Exit Button

3

Reader #4

None

Internal Exit Button

Four Door Control

1

Reader #1

None

Internal Exit Button

2

Reader #2

None

Internal Exit Button

3

Reader #3

None

Internal Exit Button

4

Reader #4

None

Internal Exit Button

Refer to the list of compatible readers.
- SSA-P400(T) : 26Bit Wiegand Reader
- SSA-P401(T) : 34Bit Wiegand Reader

DC +12V

GND

Reader #4

Reader #3

Reader #2

GND

D1

D0

DC+12V

Reader #1

Advertising