Rs-422 communication port connection (standalone), Rx+ rx- tx+ tx – Samsung SSA-P401 User Manual

Page 19

Advertising
background image

English

19

INSTALLATION AND EXTERNAL CONNECTION

RS-422 Communication Port Connection (Standalone)

The RS-422/RS-232 converter is required to establish RS-422 communications. Connect the 9-pin connector of
the RS-422/RS-232 converter as follows:

Connect RS-422 TX(-) to the RX(-) port of the converter.

Connect RS-422 TX(+) to the RX(+) port of the converter.

Connect RS-422 RX(-) to the TX(-) port of the converter.

Connect RS-422 RX(+) to the TX(+) port of the converter.

Connect the 9-pin connector of the RS-422/RS-232 converter to the serial COM port of the computer.

Install and launch the application (SAMS).

- Check the location of the communication port.

1.

2.

3.

4.

5.

6.

T+ T- R+ R-

RxD

TxD

Power

RS-422/232
Converter

RS-232C

MAX. 1200m

HOST

TX-

TX+

RX-

RX+

RX+
RX-

TX+
TX-

Advertising