Processing unit, Cable, Processing unit to sensor unit cable – Simrad HS50 User Manual
Page 16: Interface, 8 cable, 9 interface

Simrad HS50 Heading Sensor
8
20221081 / F
Processing unit
Enclosure material: .......................................Anodized aluminum
Enclosure protection: ............................................................. IP44
Operating temperature range: ................0 to +55ºC (32 to 131°F)
Storage temperature range: ................. -20 to +60ºC (-4 to 140°F)
Safe distance to compass: ........................................ 0.2 m (0.7 ft)
2.8 Cable
Processing unit to sensor unit cable
Type: ......................................................2x2x0.5 mm
2
with shield
Maximum length:................................................... 100 m (328 ft)
Diameter: ..............................................................10 mm (0.4 in.)
Flame retardation:.....................................................IEC 332-3/A
2.9 Interface
Configuration:....... Display unit connected to the Processing unit
Data outputs:........................................Three RS-232 serial lines,
Three RS-422 serial lines,
Ethernet UDP/IP
Data inputs:.................... One RS-232 and one RS-422 serial line
DGPS corrections: ..... RTCM 104 version 2.2 and SAPOS
®
EPS
Baud rate:...........................................................Max. 38.4 kBaud
HDT, ROT, GGA and GLL data update rates:.......... Up to 20 Hz
HDT, ROT, GGA and GLL data delay:...............Less than 50 ms
ZDA and VTG data update rate:....................................Max 1 Hz
VTG data delay:......................................................... Max 1.5 sec
ZDA data delay:..................................................................... 1 ms
Data output formats:
• NMEA 0183 ZDA, GGA, GLL, VTG, HDT, ROT, GSA,
GRS and proprietary messages PSXN,20. The PSXN,20
message include position, height and heading quality
information
• RD Instrument ADCP proprietary NMEA format, "PRDID".
• Radar clock data