INSTALLATION

20221081 / F

13

Pedestal mounting (option)
An optional mounting pedestal (part no. 20213021) can be
delivered from Simrad by request. This pedestal is designed for
2-inch mast mounting.

Attach the pedestal to the Sensor unit with the four screws and
washers similar to the bracket mounting option described on
page 12.

self-bonding tape

Connector with

Cable duct

Cable ties

Pipe clamps

1

Lift the Sensor unit in the preferred direction
on the mast. Use two pipe clamps with
preferred size for mounting the Sensor unit
pedestal to the mast top.

2

Ensure that the Sensor unit is mounted in
such a way that torsion movement relative to
the mast is kept at an absolute minimum.

All nuts should be secured with washers or by
self-locking nuts.

Connect the cable from the Processing unit to the cable as
described in page 11.

Cable wiring

The wiring for the Sensor unit cable in the Processing unit
terminals is as follows:

Cable Wire No.

Signal Description

Processing Unit

Connector P201

Label

Screen Cable

shield GND

4 Transmit

COMM+

3 Receive

COMM-

2 +24

VDC

PWR+

1 Power

ground

PWR-