Appendix d adaptec hostraid setup guidelines – SUPER MICRO Computer 5015M-U User Manual

Page 111

Advertising
background image

Appendix D: Adaptec HostRAID Setup Guidelines

D-1

Appendix D

Adaptec HostRAID Setup Guidelines

After all the hardware has been installed, you must fi rst confi gure the Adaptec Embedded

SATA RAID before you install the Windows operating system. The necessary drivers

are all included on the Super Micro bootable CDs that came packaged with your

serverboard. Note: The following section provides information on the Adaptec SATA

RAID Driver based on the Intel ICH7R South Bridge Controller.

D-1

Introduction to the Intel ICH7R I/O Controller Hub

Located in the South Bridge of the Intel 3010 Chipset, the ICH7R I/O controller

hub provides the I/O subsystem with access to the rest of the system. It supports

a single-channel Ultra ATA/100 Bus Master IDE controller (PATA) and an Adaptec

SATA Host controller, which supports up to six Serial ATA drives, up to two RAID

volumes and up to four drives in RAID confi gurations. (See the table below for

details.)

Raid Level Create Via

When Appropriate

RAID 0

Quick Init

Creating a RAID 0 on new drives

RAID 0

Migrate*

Creating a RAID 0 from one new drive and
one drive with data you wish to preserve

RAID 1

Build*

Any time you wish to create a RAID 1, but especially if
you have data on one drive that you wish to preserve

RAID 1,
RAID 10

Clear

Creating a RAID 1 or RAID 10 on new drives, or when
you want to ensure that the array contains no data after
creation.

RAID 1,
RAID 10

Quick

Init

Fastest way to create a RAID 1 or RAID 10
Appropriate when using new drives

Advertising