Chapter 6: optional interface, Optional serial interface – Star Micronics Star SCP700 Series User Manual
Page 25
Advertising

21
Chapter 6: Optional Interface
Optional serial interface
Use a thin flat-blade screwdriver or some other similar object to change DIP
switch settings on the optional serial interface board.
The following table shows all the possible settings for the DIP switches. All
switch settings, except for 1-7 and 1-8, are ON when the printer is shipped from
the factory.
Switch
Parameter
ON
OFF
1
Baud Rate
See table below
2
3
Data Length
8 bits
7 bits
4
Parity Check
Disabled
Enabled
5
Parity Selection
Odd
Even
6
Handshake
DTR/DSR
XON/XOFF
7
Serial I/F Pin 6 Reset Signal
Active
Inactive
8
Serial I/F Pin 25 Reset Signal
Active
Inactive
Baud Rate
Switch 1
Switch 2
2400BPS
OFF
OFF
4800BPS
ON
OFF
9600BPS
ON
ON
19200BPS
OFF
ON
ON
OFF
1
2
3
4
5
6
7
8
Advertising