background image

Connection for power

RJ-45 Connection

7. Pull retractable safety cable

from bottom of camera and
insert into hook, inside upper
housing.

(figure 7a)

1. Remove junction box cover with supplied hex tool to view inner connection block.

(figure 1a)

Inner connection block exposes connections for power, video, alarm input/output as well
as dip switches for selecting camera ID, protocol, baud rate and termination.

(figure 1b)

See

manual for proper settings.

2. Attach wall mount to wall with supplied anchor bolts and make connections.

Inner Box connections

*Note for RS-485 Connection:
GVI uses solid colored wire to represent posi-
tive (+) and striped wire for negative(-) polar-
ity. Regardless of the wire color you choose
make sure polarity matches on both ends of
the connection

Cable connection for dome. Connect
cable from mount into upper housing

Inside view of upper housing

3. Remove camera mechanism from upper housing.

(figure 3a)

4. Use Teflon tape (included) to wrap around pipe fitting.

(figure 4a)

5. Attach safety cable to neck of mount.

(figure 5a)

6. Attach other end of safety cable to housing

(figure 6a)

and now screw in upper

housing to mount pole, bring in cable from pole mount and attach.

(figure 6b)

Safety cable to mount

Teflon tape for tight connection

Safety cable to housing

1a

1b

2a

2b

4a

5a

6a

3a

Retractable safety cable

6b

7a

SCC/SNC-C7478 Installation Guide


SAMSUNG | GVI Security, Inc

.