Sanyo DC INVERTER SPLIT SYSTEM AIR CONDITIONER C1271 User Manual

Page 105

Advertising
background image

17

Cross-Sectional

(A)+(B)

(A) Power Supply Wiring Length (ft)

(C) Control

Fuse or Circuit

Area (AWG)

(B) Power Line Length (ft)

Line Length (ft)

Model

(#14)

(#12)

(#14)

Breaker Capacity

C1271, CL1271

131 (Max.)

230 (Max.)

65 (Max.)

20A

C1872, CL1872

131 (Max.)

230 (Max.)

98 (Max.)

20A

# ... AWG (American Wire Gauge)

Table 4

Be sure to comply with local codes on running the

wire from the indoor unit to the outdoor unit (size

of wire and wiring method, etc.).

Each wire must be firmly connected.

No wire should be allowed to touch refrigerant

tubing, the compressor, or any moving part.

Be sure to connect the power supply line to the

outdoor unit as shown in the wiring diagram. The

indoor unit draws its power from the outdoor unit.

Do not run wiring for antenna, signal, or power

lines of television, radio, stereo, telephone, secu-

rity system, or intercom any closer than 3'3" (1 m)

from the power cable and wires between the

indoor and outdoor units. Electrical noise may

affect the operation.

To avoid the risk of electric shock, each air con-

ditioner unit must be grounded.

For the installation of a grounding device,

please observe local electrical codes.

Grounding is necessary, especially for units

using inverter circuits, in order to release

charged electricity and electrical noise caused

by high tension.

Otherwise, electrical shock may occur.

Place a dedicated ground more than 7' (2 m)

away from other grounds and do not have it

shared with other electric appliances.

*

A disconnect switch may be required by
national or local codes.

NOTE

WARNING

WARNING

CAUTION

Always comply with national and local code
requirements.

CAUTION

Fig. 7a

(C1271, CL1271)

Disconnect
switch

*

1

2

3

1

2

3

4

5

6

Grounding line

115V

115V

115V

INDOOR

UNIT

OUTDOOR

UNIT

Field supply

Grounding
line

L

N

Po

w

e

r

su

pply

S

ing

le pha

s

e 115V 60HZ

Terminal

Terminal

(A)

(B)

(C)

(B)

Fig. 7b

(C1872, CL1872)

Disconnect
switch

*

1

2

3

1

2

3

4

5

6

Grounding line

230/208V

230/208V

230/208V

INDOOR

UNIT

OUTDOOR

UNIT

Field supply

Grounding
line

L

1

L

2

Po

w

e

r

su

pply

S

ing

le pha

s

e 2

3

0/20

8

V 60HZ

Terminal

Terminal

(A)

(B)

(C)

(B)

WIRING SYSTEM DIAGRAM

08-221 XS1271 9/12/08 2:52 PM Page 17

Advertising