Sanyo DC INVERTER SPLIT SYSTEM AIR CONDITIONER C1271 User Manual

Page 105

Advertising
background image

17

Cross-Sectional

(A)+(B)

(A) Power Supply Wiring Length (ft)

(C) Control

Fuse or Circuit

Area (AWG)

(B) Power Line Length (ft)

Line Length (ft)

Model

(#14)

(#12)

(#14)

Breaker Capacity

C1271, CL1271

131 (Max.)

230 (Max.)

65 (Max.)

20A

C1872, CL1872

131 (Max.)

230 (Max.)

98 (Max.)

20A

# ... AWG (American Wire Gauge)

Table 4

●

Be sure to comply with local codes on running the

wire from the indoor unit to the outdoor unit (size

of wire and wiring method, etc.).

●

Each wire must be firmly connected.

●

No wire should be allowed to touch refrigerant

tubing, the compressor, or any moving part.

●

Be sure to connect the power supply line to the

outdoor unit as shown in the wiring diagram. The

indoor unit draws its power from the outdoor unit.

●

Do not run wiring for antenna, signal, or power

lines of television, radio, stereo, telephone, secu-

rity system, or intercom any closer than 3'3" (1 m)

from the power cable and wires between the

indoor and outdoor units. Electrical noise may

affect the operation.

●

To avoid the risk of electric shock, each air con-

ditioner unit must be grounded.

●

For the installation of a grounding device,

please observe local electrical codes.

●

Grounding is necessary, especially for units

using inverter circuits, in order to release

charged electricity and electrical noise caused

by high tension.

Otherwise, electrical shock may occur.

●

Place a dedicated ground more than 7' (2 m)

away from other grounds and do not have it

shared with other electric appliances.

*

A disconnect switch may be required by
national or local codes.

NOTE

WARNING

WARNING

CAUTION

Always comply with national and local code
requirements.

CAUTION

Fig. 7a

(C1271, CL1271)

Disconnect
switch

*

1

2

3

1

2

3

4

5

6

Grounding line

115V

115V

115V

INDOOR

UNIT

OUTDOOR

UNIT

Field supply

Grounding
line

L

N

Po

w

e

r

su

pply

S

ing

le pha

s

e 115V 60HZ

Terminal

Terminal

(A)

(B)

(C)

(B)

Fig. 7b

(C1872, CL1872)

Disconnect
switch

*

1

2

3

1

2

3

4

5

6

Grounding line

230/208V

230/208V

230/208V

INDOOR

UNIT

OUTDOOR

UNIT

Field supply

Grounding
line

L

1

L

2

Po

w

e

r

su

pply

S

ing

le pha

s

e 2

3

0/20

8

V 60HZ

Terminal

Terminal

(A)

(B)

(C)

(B)

WIRING SYSTEM DIAGRAM

08-221 XS1271 9/12/08 2:52 PM Page 17