Step 4: (gravity drain models only), Standpipe installation – Speed Queen FLW1525C User Manual

Page 13

Advertising
background image

Installation

11

802733

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Standpipe Installation

Place the drain hose into the standpipe.

Remove the beaded tie-down strap from accessories
bag and place around standpipe and drain hose and
tighten strap to hold hose to standpipe. Refer to
Figure 7. This will prevent the drain hose from
dislodging from drain receptacle during use.

Figure 7

Step 4: (Gravity Drain Models Only)
Connect Drain Outlet to Drain System

Remove drain fitting (four inches long) and hose
clamp from accessories bag. Insert drain fitting into
drain outlet hose. Clamp hose and fitting.

Connect the drain fitting to a vented drain system
using a flexible connection (obtain locally). Inside
diameter of fitting is 1.53 in. (3.89 cm) and outside
diameter is 1.66 in. (4.22 cm). The drain system must
be vented to prevent an air lock or siphoning.

IMPORTANT: Increasing the drain hose length,
installing elbows, or causing bends will decrease
drain flow rates and increase drain times,
impairing machine performance.

Figure 8

FLW1964N

1

Standpipe 2 in. (5.08 cm) or 1-1/2 in. (4 cm)

Flw1964N

1

24 TO 36 in.

(61 TO 91.44 cm)

RECOMMENDED

HEIGHT

FLW1935N

1

Drain Trough

2

Drain Outlet Hose

Flw1935N

2

1