Installation

13

802733

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Step 6: Remove the Shock Sleeves and
Shipping Brace

Remove front access panel by removing the two screws
at the bottom of the panel.

Remove the five bolts and lockwashers from shipping
brace with 9/16 in. wrench and remove brace. Refer to
Figure 10. Four bolts are located on the washer base
and one is holding the brace to the weight. Remove all
four shock sleeves by pulling on the yellow rope.
Remove label from front side of front access panel and
place on backside of front access panel for future
reference.

NOTE: The shipping brace, bolts, washers and
shock sleeves should be saved and MUST be
reinstalled whenever the washer is moved more
than four feet. Refer to User-Maintenance
section
for instructions. Do not lift or transport washer
from front or without shipping materials installed.

Store the shipping materials in the accessories bag.
Save materials for use whenever the washer is moved.

Reinstall front access panel.

IMPORTANT: DO NOT tip washer more than
6 inches (152.4 mm) in any direction after shipping
brace has been removed. Shock absorbers may
separate and damage to washer may result. For
leveling purposes, the washer may be tilted a
maximum of 6 inches (152.4 mm) in any direction.

Figure 10

Step 7: Wipe Out Inside of Wash Drum

Before using washer for the first time, use an all-purpose
cleaner, or a detergent and water solution, and a damp
cloth to remove shipping dust from inside wash drum.

Figure 11

Step 8: (Supply Injection Models Only)
Connect External Supplies to Washer

IMPORTANT: Undiluted chemical dripping can
damage the washer.

1. Remove two nozzles from accessories bag. Use

either the 3/8 inch or 1/4 inch nozzles, depending
on the diameter of the dispenser tubing used.

2. Attach nozzles to rear of machine. Connection

point located on cabinet, above water mixing
valve. Refer to Figure 12.

3. Connect supply hoses to nozzles and secure with

hose clamps (obtain locally). Refer to Figure 12.

NOTE: Hoses can be connected to either nozzle.

4. Refer to supply injection system instructions and

label inside washer junction box cover
(Figure 13) for electrical connection.

Do not attempt to make supply injection electrical
connections to points other than those provided
specifically for that purpose by the factory.

5. Refer to supply injection system instructions for

details on operation.

FLW2124N

1

Shock Sleeves

2

Motor Mount

3

Hooked End of Shipping Brace

4

Bolts and Lockwashers

FLW2124N

2

1

4

3

FLW2115N