If problems occur, Error checklist – Sennheiser SKM 5200 User Manual

Page 26

Advertising
background image

28

If problems occur ...

Error checklist

If problems occur that are not listed in the above table or if the
problems cannot be solved with the proposed solutions, please
contact your local Sennheiser agent for assistance.

Problem

Possible cause

Possible solution

No operation
indication

Batteries are flat or
inserted incorrectly,
battery pack is flat

Replace the batteries or
check if they are
inserted correctly or
recharge the battery
pack

Transmitter
cannot be
switched off/
Settings cannot
be changed

Lock mode is activated

Deactivate the lock
mode (see
“Deactivating the
autolock function
temporarily” on page
16)

Receiver:
No RF signal

Transmitter and
receiver are not on the
same channel

Set transmitter and
receiver to the same
channel

Transmitter is out of
range

Check the squelch
threshold setting
or reduce the distance
between receiving
antenna and
transmitter

Weak signal

Antenna signal is
attenuated

Do not clasp the
antenna section

Audio signal
has a high level
of background
noise

Transmitter’s input
attenuation is adjusted
too high

See “Adjusting the
microphone sensitivity
– ATTEN” on page 25

Receiver’s output level
is adjusted too low

Increase the line output
level

Audio signal is
distorted

Transmitter’s input
attenuation is adjusted
too low

See “Adjusting the
microphone sensitivity
– ATTEN” on page 25

Receiver’s output level
is adjusted too high

Reduce the line output
level

SKM 5200_512717_0506_Sp6.book Seite 28 Donnerstag, 7. Dezember 2006 3:28 15

Advertising